MRTALPCH6-DC3(RC): #35125
Rev 1.0/12-19
12
For the
2A
4-pad configuration (fig. 2A):
Do not connect hoses from pad frame
extensions in 4-pad configuration.
1) Make sure the red hose (R) from the
vacuum pad on a pad frame extension is
disconnected
as shown.
2) Connect the blue hose (B) as shown.
3) Repeat steps 1-2 for the other frame
extension.
3A
The 2 vacuum circuits correspond with their matching vacuum gauges
(fig. 3A).
Make sure quick connectors
seal completely and all
vacuum hoses function correctly
(see “Vacuum Test” on page 32).
Note: The gauge face colors do
not
correspond with the circuit colors.
Connecting/Disconnecting Vacuum Hoses
•
QUICK CONNECTOR
1 Female End
2-3 Male Ends
To connect a vacuum hose, push the
male and female ends of the quick
connector together until they lock.
• To disconnect the vacuum hose, move
the release ring on the female end until
the quick connector separates.
ASSEMBLY