Number of instances: 11
Instance Attributes
Attribute
ID
Need in
Implementation
Access Rule
Name
DeviceNet
Data Type
Data Value
1 Required
Get/Set
1,2
ModuleReference
UINT For
configuration
tool
use.
2 Required
Get/Set
1,2
ParameterSize
USINT
Number of parameter
bytes required by this
slot
3 Required
Get/Set
2
Parameters
Array of USINT Parameter bytes for
this slot – array size is
set by attribute 2
4 Required
Get/Set
2
ConfigByte
USINT
Configuration byte for
this slot
5
Required
Get
SlotStatus
USINT
Slot status code (see
below)
6 Required Get
Channel0Status
USINT
7 Required Get
Channel1Status
USINT
8 Required Get
Channel2Status
USINT
9 Required Get
Channel3Status
USINT
10 Required Get
Channel4Status
USINT
11 Required Get
Channel5Status
USINT
12 Required Get
Channel6Status
USINT
13 Required Get
Channel7Status
USINT
Channel status code
(see below)
14 Required Get
Channel0Type
USINT
15 Required Get
Channel1Type
USINT
16 Required Get
Channel2Type
USINT
17 Required Get
Channel3Type
USINT
18 Required Get
Channel4Type
USINT
19 Required Get
Channel5Type
USINT
20 Required Get
Channel6Type
USINT
21 Required Get
Channel7Type
USINT
Channel type code
(see below)
The Channel Type
code is zero if the
corresponding
Channel Status code
is zero
22 Conditional Get/Set
ParamByte1 USINT
23 Conditional Get/Set
ParamByte2 USINT
24 Conditional Get/Set
ParamByte3 USINT
25 Conditional Get/Set
ParamByte4 USINT
26 Conditional Get/Set
ParamByte5 USINT
27 Conditional Get/Set
ParamByte6 USINT
28 Conditional Get/Set
ParamByte7 USINT
29 Conditional Get/Set
ParamByte8 USINT
30 Conditional Get/Set
ParamByte9 USINT
31 Conditional Get/Set
ParamByte10 USINT
32 Conditional Get/Set
ParamByte11 USINT
33 Conditional Get/Set
ParamByte12 USINT
34 Conditional Get/Set
ParamByte13 USINT
35 Conditional Get/Set
ParamByte14 USINT
36 Conditional Get/Set
ParamByte15 USINT
37 Conditional Get/Set
ParamByte16 USINT
38 Conditional Get/Set
ParamByte17 USINT
39 Conditional Get/Set
ParamByte18 USINT
40 Conditional Get/Set
ParamByte19 USINT
41 Conditional Get/Set
ParamByte20 USINT
42 Conditional Get/Set
ParamByte21 USINT
43 Conditional Get/Set
ParamByte22 USINT
44 Conditional Get/Set
ParamByte23 USINT
See Semantics