Page 1: ...50 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA CIRCULAR GRILL 1000 Specialty Grill Gas Fired Grill CIRCULAR GRILL WS LHPCGG D 1000 C DOC NO M0016 00 REVISED June 2015 Installation and Operation Manual ...

Page 2: ...6 00 info woodstone corp com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 TABLE OF CONTENTS TABLE OF CONTENTS CIRCULAR GRILL 3 CAUTIONS AND WARNINGS 4 SPECIFICATIONS 6 RECEIVING THE GRILL 7 CLEARANCES VENTING 8 UTILITY CONNECTIONS 9 LIGHTING INSTRUCTIONS 11 MAINTENANCE 13 TROUBLESHOOTING 14 L...

Page 3: ...2015 Doc no M0016 00 info woodstone corp com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CIRCULAR GRILL SPECIALITY COOKING EQUIPMENT WS LCHGC D 1000 C GAS FIRED GRILL ADDITIONAL COPIES AVAILABLE UPON REQUEST CIRCULAR GRILL CASCADE ROTISSER...

Page 4: ...ecommended that this oven be installed maintained and serviced by authorized professionals DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT Con...

Page 5: ...traint on the appliance If disconnection of the restraint is necessary reconnect this restraint after the appliance has been returned to its originally installed position A MAJOR CAUSE OF FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS This equipment has b...

Page 6: ...0 DWN BY SHEET Bellingham WA 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES TOLERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE woodstone net dfs CAD 0 Pn CSI L LHPCGG_Circular Grill Gas Circular Grill 1000 dft THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION O...

Page 7: ...1 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 RECEIVING THE GRILL UNLOADING THE GRILL The crated Circular Grill 1000 weighs 580 lbs Take care not to hit the legs or casters that protrude from the bottom of the unit MOVING THE GRILL The crated grill can be moved using a forklift if space allows Alternatively an appropriately rated pallet jack can ...

Page 8: ...m sides of grill to non combustible construction is 36 to allow for combustion air Floor The unit is suitable for installation on combustible floors WARNING Do not pack required air spaces with insulation or other material Do not obstruct the flow of combustion and ventilation air VENTING The Wood Stone Circular Grill must be vented using a Listed Type 1 exhaust hood or one constructed in accordan...

Page 9: ...se With Gas Fuel ANSI Z21 41 or CSA 6 9 ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Use the holes in the lower rails of the rotisserie cabinet to attach the restraining device s All connection...

Page 10: ...s and pipe connections for leaks Use approved gas leak detectors soap solutions or equivalent over and around the fittings and pipe connections DO NOT USE A FLAME TO TEST FOR LEAKS Wood Stone recommends that a manual individual appliance shutoff valve be supplied located between the grill and the main gas supply and be left readily accessible MANIFOLD PRESSURE GAS RATING This appliance is equipped...

Page 11: ...sition Hold down while depressing and holding down the red IGNITION button 1 Push and turn Burner Control knobs to OFF position 2 Push and turn Pilot knob to OFF 2 Keep red IGNITION button depressed until visually confirming the pilot has lit through the Pilot view port then release 3 Turn Pilot knob to the ON position To adjust flame height depress Burner Control knob turn to the flame height des...

Page 12: ... not to scratch the plate surface by applying too much pressure during the cleaning process END OF DAY Remove grease trays and clean using an approved mild detergent hot water and an approved sanitizing solution Alternatively these items can be cleaned in a dishwasher CLEANING THE COOKING SURFACE Custom Branding Grates should be removed from the grill for general cleaning The build up of carbon re...

Page 13: ...NCE 1 With grill cool remove cooking grates using two Quad Grate Removal Tools 2 Clean the 6 Grill Burner Radiants and Pilot Zip Tube covers using a wire brush being careful not to damage the spark ignitor assemblies Wipe away any debris 3 Clean fallen debris from the four grease trays 1 Verify Pilot knob is in OFF position 2 Unscrew the Ignitor button to access the AA battery 3 Replace battery pl...

Page 14: ...w gas pressure Increase pressure at main or grill regulator Cracked burner head Replace burner Low flame on zip burner Raise pilot flame Clogged orifice Clean orifice Low gas pressure Increase pressure at main or appliance regulator Manual shut off valve partially closed Open valve fully Gas line too small Replace gas line Flame blowing away from generator or thermocouple TC Eliminate drafts Gener...

Page 15: ...ebox 8 In wood fired equipment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sp...