FLUE ADAPTER, MS-4
MOUNTAIN SERIES MS-4 OVENS: FLUE ADAPTER INSTALLATION
The flue adapter unit is designed to facilitate connection to a round duct� Use the provided stainless steel screws and sealant
provided to attach the flue adapter to the exhaust outlet on the oven (203mm (8") I�D�)
Note:
If using a Selkirk or other modular-type duct, attach according to the manufacturer’s instructions� Otherwise, the duct must
be attached with a full perimeter weld� Grease-rated duct is required throughout the system� If the oven is going to be enclosed,
the flue adapter and exhaust outlet must be wrapped with an insulating material approved for use with a grease-duct�
If the oven is
to be enclosed,
wrap with
insulation
approved for
use with a
grease duct.
The flue adapter is for direct connection to a duct system ONLY.
DO NOT install if oven is installed under an exhaust hood.
Note:
Vent
Shield not
shown for
clarity
Apply the supplied
Engineered Grade Ceramic
Sealing Compound to
the underside of the Flue
Adapter with an unbroken
bead around the perimeter,
and around each individual
screw hole�
Then fasten with the
supplied screws�
Underside of Flue Adapter showing
where Ceramic Sealing Compound
should be applied
FLUE ADAPTER INSTALLATION
(If not already installed)
FLUE ADAPTER ATTACHED TO OVEN FLUE COLLAR
203mm (8") I.D.
Flue adapter
Vent Shield not
required for
direct connect
installations.