Mountain Series CE
Installation and Operation Manual
UTILITIES
ELECTRICAL
The oven is rated at 230 VAC, 2 A, 50 Hz� The rating also appears on the data plate� It is recommended that the oven be
connected to its own individual branch circuit� Electrical diagrams are located on the Junction Box and also at the end of this
manual�
GAS
SV-1 and SV-2 are the gas control valves that operate the underfloor infrared burner and the interior radiant burner, respectively�
RFG ovens do not have an SV-1 valve�
SV-1 is the gas control valve that operates the Underfloor Infrared (IR) Burner� The manifold pressure is checked at the outlet port
on the SV-1 gas valve�
SV-2 is the gas control valve that operates the interior Radiant Burner� SV-2 is located at the rear left beneath the oven� The
manifold pressure test port for the Radiant Burner is a 3�175mm (1/8") NPT plugged tap located at the base of the T-junction
between the SV-2 and the Radiant Burner�
The burner manifold pressure has been adjusted and tested at the factory� A variety of factors can influence this pressure, so be
sure to test the burner manifold pressure and adjust the valve as necessary to achieve the specified pressure�
NOTE:
The gas valve is shipped in the
ON
position�
!
Electrical Grounding:
This appliance must be electrically grounded (earthed) via the third wire
ground of the incoming AC power�
Provide Disconnect Device:
This appliance must be provided with an all-pole type disconnect
device in the incoming power supply so that the appliance can be completely isolated from the
power supply�
Terminal Strip location