Wood Stone BARREL TANDOOR Installation And Operation Manual Download Page 5

 

PG 

OF

 20

M0054.07  JULY 2019

Gas-Fired Tandoor CE   

Installation and Operation Manual

GFT-31-CE SPECIFICATIONS

WS-GFT-31-CE (ROUND AND SQUARE MODELS)

Shipping weight: 

431 Kg

(750 lbs.)

REV:

LEGEND:

PART #:

WS-GFT-31-RND

31" Tandoor.  All Shapes

General Arrangement

10/14/2013

bena

1

DWN BY:

SHEET:

Bellingham, WA 360/650-1111 www.woodstone-corp.com

DIMENSIONS ARE IN INCHES

TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°

UNLESS NOTED OTHERWISE

\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft

THE INFORMATION CONTAINED IN THIS DRAWING IS THE

SOLE PROPERTY OF WOOD STONE CORPORATION

ANY REPRODUCTION OR USE IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS

PROHIBITED

AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT

MAY REQUIRE US TO CHANGE SPECIFICATIONS

WITHOUT NOTICE.

DATE:

G

GAS INLET: 1/2" NPT
40,000 BTU, NG
40,000 BTU, LP

1 of 1

G

G

G

30 3/4"

780mm

30 3/4"

780mm

30 3/4"

780mm

O

12"

300mm

Opening

O

12"

300mm

Opening

O

12"

300mm

Opening

12 3/4"

320mm

31"

790mm

37 3/4"

960mm

6 1/4"

160mm

21 1/2"

550mm

21"

530mm

Plan view (Round)

REV:

LEGEND:

PART #:

WS-GFT-31-RND

31" Tandoor.  All Shapes

General Arrangement

10/14/2013

bena

1

DWN BY:

SHEET:

Bellingham, WA 360/650-1111 www.woodstone-corp.com

DIMENSIONS ARE IN INCHES

TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°

UNLESS NOTED OTHERWISE

\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft

THE INFORMATION CONTAINED IN THIS DRAWING IS THE

SOLE PROPERTY OF WOOD STONE CORPORATION

ANY REPRODUCTION OR USE IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS

PROHIBITED

AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT

MAY REQUIRE US TO CHANGE SPECIFICATIONS

WITHOUT NOTICE.

DATE:

G

GAS INLET: 1/2" NPT
40,000 BTU, NG
40,000 BTU, LP

1 of 1

G

G

G

30 3/4"

780mm

30 3/4"

780mm

30 3/4"

780mm

O

12"

300mm

Opening

O

12"

300mm

Opening

O

12"

300mm

Opening

12 3/4"

320mm

31"

790mm

37 3/4"

960mm

6 1/4"

160mm

21 1/2"

550mm

21"

530mm

Side view (Round)

REV:

LEGEND:

PART #:

WS-GFT-31-RND

31" Tandoor.  All Shapes

General Arrangement

10/14/2013

bena

1

DWN BY:

SHEET:

Bellingham, WA 360/650-1111 www.woodstone-corp.com

DIMENSIONS ARE IN INCHES

TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°

UNLESS NOTED OTHERWISE

\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft

THE INFORMATION CONTAINED IN THIS DRAWING IS THE

SOLE PROPERTY OF WOOD STONE CORPORATION

ANY REPRODUCTION OR USE IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS

PROHIBITED

AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT

MAY REQUIRE US TO CHANGE SPECIFICATIONS

WITHOUT NOTICE.

DATE:

G

GAS INLET: 1/2" NPT
40,000 BTU, NG
40,000 BTU, LP

1 of 1

G

G

G

30 3/4"

780mm

30 3/4"

780mm

30 3/4"

780mm

O

12"

300mm

Opening

O

12"

300mm

Opening

O

12"

300mm

Opening

12 3/4"

320mm

31"

790mm

37 3/4"

960mm

6 1/4"

160mm

21 1/2"

550mm

21"

530mm

Front view (Round)

REV:

LEGEND:

PART #:

WS-GFT-31-RND

31" Tandoor.  All Shapes

General Arrangement

10/14/2013

bena

1

DWN BY:

SHEET:

Bellingham, WA 360/650-1111 www.woodstone-corp.com

DIMENSIONS ARE IN INCHES

TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°

UNLESS NOTED OTHERWISE

\\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft

THE INFORMATION CONTAINED IN THIS DRAWING IS THE

SOLE PROPERTY OF WOOD STONE CORPORATION

ANY REPRODUCTION OR USE IN PART OR AS A WHOLE

WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS

PROHIBITED

AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT

MAY REQUIRE US TO CHANGE SPECIFICATIONS

WITHOUT NOTICE.

DATE:

G

GAS INLET: 1/2" NPT
40,000 BTU, NG
40,000 BTU, LP

1 of 1

G

G

G

30 3/4"

780mm

30 3/4"

780mm

30 3/4"

780mm

O

12"

300mm

Opening

O

12"

300mm

Opening

O

12"

300mm

Opening

12 3/4"

320mm

31"

790mm

37 3/4"

960mm

6 1/4"

160mm

21 1/2"

550mm

21"

530mm

Plan view (Square)

Note: 

Front and side 

dimensions are the 
same for the Round and 
Square models�

Air intake: Do not  

facade or cover over

UTILITY SPECIFICATIONS

Gas

12�7 mm (1/2") FBSPT inlet 
See Gas Specifications on page 

10 of this manual�

Maximum gas inlet pressure

34 mbar (1/2 psi or 14" W�C�)

Gas connection should be made using 

an approved flexible connector and the 

unit must be restrained in accordance 

with all relevant local and national codes�
Gas connection is made beneath unit  

at rear�

Venting

The Tandoor has been approved as a Type A appliance 
and may be vented using an approved exhaust 
hood� All exhaust system venting should meet the 
construction requirements of a grease duct� The 
Tandoor must be vented in accordance with all relevant 
local and national codes, and in a manner acceptable 
to the authority have jurisdiction� See Venting section 
for further details�

Summary of Contents for BARREL TANDOOR

Page 1: ...ATION 1801 W Bakerview Rd Bellingham WA 98226 USA TANDOOR CE Speciality Ovens Gas Fired Round Square and Barrel European Models TANDOOR 31 WS GFT 31 CE TANDOOR 35 WS GFT 35 CE BARREL TANDOOR WS GFT 35 CUS CE DOC NO M0054 07 REVISED JULY 2019 Installation and Operation Manual ...

Page 2: ...F CONTENTS TABLE OF CONTENTS Tandoor CE 3 Cautions Warnings 4 SPECIFICATIONS GFT 31 CE 5 GFT 35 CE 6 GFT 35 CUS CE Barrel 7 Clearances Restraints 8 Venting 9 Gas specifications 10 Lower Flashing Install Barrel 12 Lighting Instructions 13 Operation 14 Cleaning Maintenance 15 Limited Warranty 17 ...

Page 3: ...ION AND OPERATION MANUAL FOR THE WOOD STONE TANDOOR ORIGINAL INSTRUCTIONS GAS FIRED TANDOOR WS GFT 31 ROUND SQUARE WS GFT 35 ROUND SQUARE WS GFT 35 CUS BARREL CE MODELS ADDITIONAL COPIES AVAILABLE UPON REQUEST Square model shown with optional utensil rails pan rail w pans and shelf Round model Barrel model ...

Page 4: ...ea RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone corp com For prompt responses to service maintenance questions call your local distributor FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can result in pr...

Page 5: ... O 12 300mm Opening O 12 300mm Opening O 12 300mm Opening 31 790mm 37 3 4 960mm 6 1 4 160mm 21 530mm Side view Round REV LEGEND PART WS GFT 31 RND 31 Tandoor All Shapes General Arrangement 10 14 2013 bena 1 DWN BY SHEET gham WA 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES LERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE NFORMATION CONTAINED IN THIS DRAWING IS THE OLE PROPE...

Page 6: ... G O 13 330mm Opening O 13 330mm Opening 40 3 4 1040mm G O 13 330mm Opening 33 3 4 860mm 6 1 4 160mm 24 3 4 630mm Side view Round REV LEGEND PART WS GFT 35 RND 35 Tandoor All Shapes General Arrangement 10 14 2013 bena 1 DWN BY SHEET ngham WA 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES OLERANCES LINEAR 1 2 10mm ANGULAR 2 UNLESS NOTED OTHERWISE E INFORMATION CONTAINED IN THIS DRAWIN...

Page 7: ...ved 16 1 4 410mm 7 180mm 34 3 4 32 3 4 880mm 830mm Height Adjustable 11 1 2 290mm 21 530mm 21 1 2 550mm G R 7 180mm Door Swing Radius Gas Connection Made Beneath Unit G Adjustable Feet 2 50mm Front view REV LEGEND PART WS GFT 3521 BRL 3521 Barrel Tandoor General Arrangement 7 30 2019 lucasm 3 DWN BY SHEET Bellingham WA 360 650 1111 www woodstone corp com DIMENSIONS ARE IN INCHES TOLERANCES LINEAR ...

Page 8: ...his appliance is installed with casters it must be installed with the casters supplied a connector complying with local codes and a quick disconnect device complying with local codes It must also be installed with restraining means to guard against transmission of strain to the connector as specified below ATTENTION INSTALLER EQUIPMENT RESTRAINT MUST BE PROVIDED Adequate means must be provided to ...

Page 9: ...ection designed to be installed under an exhaust hood canopy The hood must be connected to a grease rated duct system The venting system must be designed and installed in accordance with all relevant codes pertaining to grease and smoke producing commercial cooking appliances Check with your local code official Airflow should be adjusted according to the requirements specified by the hood manufact...

Page 10: ...plication When using a flexible connector make sure that its design does not present any reduction in pipe diameter or other restriction Tandoor issues caused by improper pipe sizing improper shut off valves restrictive connectors or any other deficiency in the gas supply design or installation will not be covered under the Tandoor warranty THIS APPLIANCE IS NOT FOR USE WITH SOLID FUEL GAS CONNECT...

Page 11: ...upply and Pressure PROPANE LP Gas Supply and Pressure SCOPE OF APPROVALS G20 20 mbar I2H 20 AT DK ES FI IE IT PT GB SE CH GR EE LV SI HR SK and CZ G25 25 mbar I2L 25 HU G20 25 mbar I2HS 25 HU G20 25 mbar I2ELL DE G20 G25 3 20 25 mbar I2EK 20 25 NL Propane LP Maximum inlet gas pressure to the Tandoor after the external regulator if used must not exceed 34 mbar 14 W C or 1 2 psi SCOPE OF APPROVALS G...

Page 12: ...This should be done after the Flashing is lowered Lowering the Flashing The unit ships with the Strip Flashing secured into its UP position with a screw at each leg Installing the Flashing Filler Remove screws and nuts from Flashing Filler Open Control Box Position the Filler so it spans the gap between ends of the Lower Flashing Align the the holes in the Filler with the holes in the Lower Flashi...

Page 13: ... seconds until a pilot flame is established 5 Hold the Gas Control Knob down for one full minute after pilot flame is established 6 Release the Gas Control Knob the pilot flame should continue to burn NOTE If the pilot flame does not remain lit Turn the Gas Control Knob to the OFF position Wait 5 minutes and then Repeat the steps above 7 Replace Deflector Plate to the bottom of Tandoor 8 Once pilo...

Page 14: ...nob can be adjusted the appropriate heat setting depending on cooking style Settings may also vary slightly depending on gas type Natural Gas or Propane Temperature Control Knob Typical cooking flame setting 1 3 1 5 Temperature Control Knob Heat up setting 5 Temperature Control Knob First firing setting 1 FIRST FIRING The first time the Tandoor is fired the heat up should be slow and steady Hold t...

Page 15: ...he chamber walls first brush the walls with the optional In Line Floor Brush see the Tools and Accessories section of the Wood Stone website Use a moist towel water only to swirl around the chamber Any debris which falls to the bottom of the chamber can be removed as described above The stainless cabinet and granite top of the unit should be cleaned as necessary using a mild detergent and a nonabr...

Page 16: ...PG 16 OF 20 M0054 07 JULY 2019 Blank page ...

Page 17: ...te final and exclusive statement with regard to warranties THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS LIMITATIONS OF LIABILITY In the event of warranty claim or otherwise the sole obligation of Wood Stone shall...

Page 18: ...PG 18 OF 20 M0054 07 JULY 2019 Blank page ...

Page 19: ...PG 19 OF 20 M0054 07 JULY 2019 Blank page ...

Page 20: ...019 Tel 1 360 650 1111 Fax 1 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...

Reviews: