![Wood-mizer LX450-RA Safety, Setup, Operation & Maintenance Manual Download Page 92](http://html1.mh-extra.com/html/wood-mizer/lx450-ra/lx450-ra_safety-setup-operation-and-maintenance-manual_994664092.webp)
Maintenance
Blade Tensioner
5
5-10
WMdoc072919
Maintenance
See Figure 5-8.
REFILL THE TENSIONER BLOCK
See Figure 5-9.
Add an Automatic Transmission Fluid (ATF) such as Dexron III ATF to the hydraulic blade
tensioner as needed.
1.
Unscrew the tensioner handle to reveal 2” (50mm) of thread.
2.
Remove the sawmill blade housing covers and blade.
FIG. 5-8
FIG. 5-9
SM0058B
Chrome rods
Tensioner
screw handle
grease fitting
3H1032-1
Add fluid as you
pull rear piston out
AR