Maintenance
Drive Bearing
3
3-14
HDdoc012020
Maintenance
3.15 Drive Bearing
Refill the fluid in the drive-side cylinder bearing housing every 500 hours of operation. Remove the top and bot-
tom oil plugs. Pour an Automatic Transmission Fluid (ATF) such as UNIVIS J26 or Dexron III ATF into the top
hole until it begins to flow from the bottom hole. Reinstall the square oil plug to the bottom hole and the vented
oil plug to the top hole.
See Figure 3-13.
FIG. 3-13
500
Vented plug
Top hole
Bottom hole
Square plug