Troubleshooting Guide
Fuse Terminal Extension Stud
4
4-13
HDSdoc091108
Troubleshooting Guide
9.
Make sure the power feed belt is properly tightened.
Operate the loading arm hydraulic lever and read the pressure on the gauge. Hydraulic pressure is
factory-set at 2000 ±100 psi and should not need to be readjusted. The relief valve adjustment
screw shown may be used to fine-tune the hydraulic pressure.
4.9
Fuse Terminal Extension Stud
A fuse terminal extension stud is provided in the fuse box. The extension may be used to tempo-
rarily connect a battery charger or jumper cables to raise the saw head from the towing position so
the battery box lid can be removed.
CAUTION!
The fuse stud extension is designed to provide
enough power to raise the saw head only. Do not attempt to start
the engine or operate any other electrical function until direct bat-
tery charging can be performed. Do not attempt to move the saw
head by attaching jumper cables from a secondary power source
to the up/down motor terminals. Damage to the electrical system
will result.
See Figure 4-2.
1.
Remove the fuse box cover and remove the stud from its storage position inside the fuse box.
2.
Thread the extension stud on the bottom-right fuse terminal.
FIG. 4-2
Place stud on
bottom right
fuse terminal
3H0417
Extension stud
storage location