Maintenance
Drum Switches
5
5-12
HD97doc041910
Maintenance
5.6
Drum Switches
WARNING!
Disconnect and lockout power before perform-
ing any service to the electrical system. For battery-pow-
ered equipment, disconnect the negative battery terminal
cable. Failure to do so may result in injury and/or electrical
system damage.
Lubricate the up/down and power feed drum switch contacts inside the control panel
every fifty hours of operation. Use only contact grease supplied by Wood-Mizer. Remove
the control panel cover. Use a cotton swab to apply grease to the switch contact ends.
WARNING!
Drum switch grease contains Petroleum
Hydrocarbon Lubricant. Eye and skin irritant. If introduced
into eyes, flush with water for at least 15 minutes. If film or
irritation persists, seek medical attention. Wash skin with
soap and water. If ingested, do not induce vomiting - con-
tact a physician. KEEP OUT OF THE REACH OF CHIL-
DREN.
50