Setup & Operation
Replacing The Blade
Setup & Operation
15doc121912
3-9
3
moving at its lower travel limit, i.e. at the height of 25 mm above the bed.
3.2
Replacing The Blade
DANGER!
Always disengage the blade and shut off the sawmill motor
before changing the blade. Disconnect the power supply using the main
switch. Failure to do so will result in serious injury.
WARNING!
Always wear gloves and eye protection when handling
bandsaw blades. Changing blades is safest when done by one person!
Keep all other persons away from area when coiling, uncoiling, carrying or
changing a blade. Failure to do so may result in serious injury.
Adjust the blade guide arm all the way open.
Open the blade housing cover that cover the blade wheels. Turn the blade tension handle to release the
blade tension until the wheel is pulled in and the blade is lying loose in the blade housing. Lift the blade out of
the blade housing.
FIG. 3-5
Loosen bolts and adjust cam
engaging limit switch
Loosen the nut and adjust
the stop bolt
Limit Switch