General Information & Safety
Start Up Modes
General Information & Safety
SISdoc052814
1-8
1
1.9
Start Up Modes
Press the MENU button once to get to the menu selection mode. Press the UP or DOWN
button twice to find the MODE menu.
The following options are available in the MODE menu:
Set Single Clamp -
The setter clamps and checks the blade tooth. The tooth
is set if necessary. The blade is unclamped, and moved to the next tooth. The
setter skips the pattern recognition while using the Set Single Clamp mode.
The final tooth correction follows, i.e. if the toot is unbend not enough - setter
bend it, if the tooth is bended too much - setter unbend it.
Set Double Clamp -
Just like using the Set Single Clamp mode, but the blade
is clamped once more after releasing and checked for the tooth set. The pat-
tern recognition is turned off. The Set Double Clamp mode is more accurate
but more time-consuming.
Pattern Single Clamp -
The mode similar with the Set Single Clamp mode,
but the setter checks the teeth pattern. See System Parameters, for how to set
the maximum number of pattern errors (only 1 in most cases). When the num-
ber of possible errors is exceeded, the setter stops the setting process and the
"Error --- Blade Set Pattern" message appears.
Pattern Double Clamp -
Using the Pattern Double Clamp mode, the setter
works like using the Pattern Single Clamp mode, but the blade is released and
clamped again to check the tooth set. The Pattern Double Clamp mode takes
more time to set the whole blade but it is more accurate.
Inspection -
After the Inspection mode has been selected, the setter checks
the tooth set only. The process is stopped when the number of pattern errors
has been exceeded.
NOTE:
The Pattern Single Clamp and Pattern Double Clamp modes can be used only
when the tooth setter has been set to push every tooth of the blade.
Push the ENTER button to select the mode you want the setter to operate.