41004
CH3 Current Input
R/O
2 byte, Unit
:
0.001mA
HEX, Big Endian
41069
CH4 Current Output
R/W
2 byte, Unit
:
0.001mA
HEX, Big Endian
41086
CH5 Voltage Output
R/W
2byte, Unit
:
0.001V
HEX, Big Endian
41109
CH6 PWM 5V, Frequency
W/O
2 Bytes, Frequency
HEX, Big Endian
41110
CH6 PWM 5V, Duty Cycle
W/O
2 Bytes, Duty Cycle
HEX, Big Endian
41111
CH7 PWM 10V, Frequency
W/O
2 Bytes, Frequency
HEX, Big Endian
41112
CH7 PWM 10V, Duty Cycle
W/O
2 Bytes, Duty Cycle
HEX, Big Endian
LR140 A/I Register (Unreadable for Modbus protocol or LoRa GW)
41017
CH0 Voltage Input
R/O
2 byte, Unit
:
0.001V
Hex Code, Little Endian
41002
CH1 Current Input
R/O
2 byte, Unit
:
0.001mA
Hex Code, Little Endian
41019
CH2 Voltage Input
R/O
2 byte, Unit
:
0.001V
Hex Code, Little Endian
41004
CH3 Current Input
R/O
2 byte, Unit
:
0.001mA
Hex Code, Little Endian
R/O: Read Only, W/O: Write Only, R/W: support Read and Write function
7
LR100 series - Data Parsing
The LR100 forwarding data in scheduling, and those Lora packet is defined as following.
2x2 Bytes
7 Bytes
8 Bytes
1 Byte
2 Bytes
1 Byte
2 Bytes x Count of Reg.
1 Byte
2xPreambles
Time
Sensor Name
ModBus ID
Reg. Addr.
Count of Reg.
Data Payload
End Symbol
•
Preamble:
2 Bytes per preamble, and send 2 Preambles with 0x0485