Top roller
1
x1
x4
x6
x2
x6
x6
x12
x4
Profile cover cap L
Profile cover cap R
x1
x2
x1
- 6mm masonry drill bit
- 3mm HSS metal drill bit
- Power drill
- Quality silicone
- Pencil
- Tape measure
- Philips head screw driver
- Spirit level with horizontal and vertical level indicators
ST4X30
ST4X25
ST4X10
Bottom roller
Tools required
(
not supplied in hardware kit)
SCREW CUP
INSTALLATION TOOL
Handle
Upright profile cover cap
Fixed panel Top and bottom seal
Ø6
1
2
2
1
2
3
4
5
6
7
8
9
10
11
12
Wall profile
ST4X30 screw
Upright
profile
Fixed panel upright seal
Moving panel upright seal
Moving panel
Magnetic seals
Wall plug
Handle
Screw cap
ST4X10 screw
2
2
6
2
2
2
2
2
6
2
12
6
13
14
15
16
17
18
Top and bottom profile
Bottom roller
ST4X25 screw
Top roller
Squeeze gasket tool
4
2
4
2
4
1
WALL PLUG
INSTALLATION
GUIDE
2 Door Quadrant
IMPORTANT
Please familiarise yourself with the fitting instructions before
commencing fitting.
1 Check that you have the tools required
2 Check that the installation site is compatible
with size of door supplied
3 Check all the enclosure components
4 Check that the installation kit is complete
DO
NOT
attempt to install the product unless you can tick
ALL 4
boxes
as satisfactory.
The wall plugs supplied with the installation kit are for use in solid walls.
Hollow or ‘stud-partition’ walls will require alternative fixings.
Please consult a hardware supplier for the correct type.
It may also be necessary to consult your tiling supplier about the correct
method for drilling your tiles.
Any missing or damaged parts must be reported immediately.
Inspect shower enclosure before fitting. No claims will be accepted after product has been installed
For safety, it is recommend that 2 people should install the product
Use appropriate Personal Protective Equipment at all times when installing the product.
D06958
D06959
D06960
Nabis 6mm Quadrant
Nabis 6mm Offset Quad
1.The supplied fixings/wall plugs are
only
for mounting directly on solid walls.
2.It is essential that the solid, masonry/walls be inspected for adequate load-bearing capacity
prior to every installation.
3.The supplied fixings/wall plugs are
not for use
with stud walls such as plaster board, wood,
metal or fiber board.
4.Always seek professional advice to confirm wall type and appropriate type of fixing to be
used for installation.
5.Always check walls for concealed utility lines (power, gas, and water) prior to drilling the
fixing holes.
Drilling / Fixing
IMPORTANT - Installation Site
1.Ensure the top surface of the shower tray on which the enclosure will be installed is level
in every direction.
2.The tiling or other wall finishing should be effectively sealed at the tray edges.
3.Tiles should extend at least to the corners of the tray and a minimum of 2 metres from the
top of the tray.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
-
Water spray
D06961