background image

 

 

    

 

 

WOLGATE III 

 

 

 

 

 

 

 

 

TECHNICAL MANUAL 

Wolpac Controles Eficientes   Engineering Dept. MT-101                   Dec/2015                Rev.: 01

 

Summary of Contents for WOLGATE III

Page 1: ...WOLGATE III TECHNICAL MANUAL Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01...

Page 2: ...ipment Composition 5 5 Technical Specifications 6 6 Installation 7 7 Turning on the equipment 11 8 Integration 12 9 Instructions for Use 13 10 Mechanism 14 11 Preventative Maintenance 15 12 Lubricants...

Page 3: ...now at your disposal Additional clarifications comments and suggestions on this manual can be obtained through the technical support division exercised by our affiliate ATA SERVICE Site www wolpac com...

Page 4: ...of the information is strictly limited to persons previously authorized by Wolpac Reproduction transcription server storage and translation into any language of this document or part thereof is not pe...

Page 5: ...rrying large objects With sophisticated design the Wolgate III applies to various architectural environments and designs it can be used in both directions of passage controlled by validation systems a...

Page 6: ...ec 2015 Rev 01 Page 5 4 Equipment Composition Typical Unit 1 Carbon steel structure internal 2 Brushed stainless steel finish 3 Glass panel 4 Glass cover 5 Operation pictogram 6 Side LED 7 Upper front...

Page 7: ...gnetic brake after the glass returns to its original position Power Outage In cases of power outage or emergency events the equipment is designed to open in both directions returning to normal operati...

Page 8: ...amage must be reported to the carrier and if necessary report the incident to Wolpac Please have the Technical Manual on hand as provided by Wolpac Wolpac is not responsible for any injury or damage o...

Page 9: ...out the presence of solid liquid and gaseous polluting components that may corrode cables and metal components of the equipment Caution Do not expose the equipment to poor weather conditions or direct...

Page 10: ...h voltage cabling or radio frequency cabling electric motors and other machines Position the conduits as far away from the equipment anchor holes on the floor as possible All cables and conduits are p...

Page 11: ...Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 10 Detail Attachment of the equipment Detail of the installation with baluster optional Cable passage area...

Page 12: ...ograms flash red until referencing is completed b During referencing the glass panel opens fully to both sides and then stops in the central position c At the end of referencing the LEDS and pictogram...

Page 13: ...ons described above are only compatible with the readers indicated in the table below For other models the integration is the customer s responsibility Pos Configurations Code Frame Glass Application...

Page 14: ...will cancel the release and will be ready to receive the release for the next user Notes The equipment should be used by one person at a time for users with special needs the assistance of one more p...

Page 15: ...oder without release of the user activating a locking mechanism with electromagnetic operation and preventing passage Anti return device of the turnstile type locked by electromagnetic drive with capa...

Page 16: ...intensity of the flow of people Check that the displacement of the lock occurs smoothly observing the action of the speed reducer Check if the locking component such as the electromagnetic brake has...

Page 17: ...ature wear of the mechanical parts of the equipment subject to abrasion and corrosion actions it is recommended to use the following lubricant s according to the table below As well as in the parts an...

Page 18: ...Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 17 13 Exploded View of the Mechanism...

Page 19: ...Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 18 13 List of Mechanism Parts...

Page 20: ...Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 19 14 Wiring diagram PWDM II module...

Page 21: ...Wolpac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 20 15 General dimensions...

Page 22: ...egrity and the shipping and return expenses are the customer s responsibility e Products sent to the Authorized Centers should be accompanied by a brief description of the problem presented f Wolpac i...

Page 23: ...ac Controles Eficientes Engineering Dept MT 101 Dec 2015 Rev 01 Page 22 WOLPAC CONTROLES EFICIENTES Comercial e F brica Rua Iijima 554 Ferraz de Vasconcelos SP Brasil Tel 5511 4674 8000 www wolpac com...