94
If the appliance shows a malfunction not noted on the schedule above or if you
have checked all items on the above schedule but the problem still exists, please
contact the customer service.
7.1 Error codes
C
ODE
P
OSSIBLE CAUSES
M
EASURES
F3 / F4
Temperature sensor of the
induction coil is defective.
Contact the aftersales service.
F9 / FA
Temperature sensor of the
IGBT
*
.
Contact the aftersales service.
E1 / E2
Abnormal supply voltage.
Please inspect whether the
voltage is normal.
Power on after the power
supply is normal.
E3
High temperature of the
induction coil sensor.
Contact the aftersales service.
E5
High temperature of the
IGBT sensor.
Please restart after the
appliance has cooled down.
*
IGBT
= insulated-gate bipolar transistor
➢
A semiconductor device to control the load power supply.
8. Technical data
T
ECHNICAL DATA
*
:
Model
Induction hob
Control panel
Touch Control / Sliding sensor
Material
Schott Ceran
Diameters of the cooking zones/mm
4*180 mm / 1* 210 mm
Cooking zones
5 (incl. 2 flexible cooking zones)
Power of cooking zone/front right
1500 / 2000 W / Boost function
Power of cooking zone/back right
2000 / 2600 W / Boost function
Power of cooking zone/front left
2000 / 2600 W / Boost function
Power of cooking zone/back left
1500 / 2000 W / Boost function