Page 12
Integrated Modules
Integrated Modules
Electronics and Gas Theory
2-2
#826498 - Revision B - December, 2016
ELECTRONICS
This section describes the basic operation of the module electronics and how the touch pad responds to input com-
mands. The electronics operation of the CE152TF/S, CI152TF/S, SM15TF/S, FM15TF/S, GM15TF/S, and the
TM15TF/S are very similar. Model specific information is listed below the general operation.
Touch Pads
Global Touch Pads - All Models
LOCK
- Locks or unlocks the entire unit. Touch and hold for 3 seconds. Acceptance beep when state
•
changes. Padlock is displayed when locked.
ALL OFF
- Disables entire unit. Red circle displayed when any heating component is in use.
•
“+”
- Adds time to the count down timer. Valid Selection beep to acknowledge touch.
•
“-”
- Decreases time to the count down timer. Valid Selection beep to acknowledge touch.
•
TIMER
- Activate and deactivate the timer. Valid Selection beep to acknowledge touch.
•
Control Zone Pads
ON/OFF
- Enables or disables individual control zone.
•
SIM
- sets power to level 1.
•
MLT
- sets power to level 1.
•
LO
- sets power to level 1.
•
HI
- sets power to level 10.
•
ZONE 2 - CE152TF/S
- Activates Zone 2 on hobs with two or more zones.
•
BOOST - CI152TF/S
- sets power to Boost and adjusts adjacent power levels as required by the induction
•
power sharing scheme. Toggles Boost off if already engaged.
BRIDGE - TM15TF/S
- Activates adjacent induction coil to same power level.
•
DRAIN - SM15TF/s
- enables or disables the electronic drain valve.
•
“+” (temperature) - SM15TF/S and FM15TF/S
- increases the set temperature by one degree.
•
“-” (temperature) - SM15TF/S and FM15TF/S
- decreases the set temperature by one degree.
•
‘’ . . . .”
- Sets power to levels 2 through 9.
•
Annunciator - All Models
Unit must be in idle mode to adjust annunciator.
•
Adjust annunciator volume and frequency in user options mode. See Frequency Duration and Selection
•
Chart on the next page.
Factory default setting for volume is medium.
•
Factory default setting for frequency is medium.
•
Low frequency is 1.5 kHz. Medium frequency is 2.0 kHz. High Frequency is 2.5 kHz.
•