This kit is for DF3050, DF3650, DF4850, DF6050 models,
and is intended to convert from liquid propane to natural
gas.
Note
: Depending on the model, additional components
may be included with this kit, but not used.
WARNING
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation
of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
WARNING
Turn off the power and gas to the product before starting
this procedure.
SURFACE BURNER RATING
The front left burner is 20,000 Btu. Any additional front
burners to the right are 18,000 Btu. The rear left burner is
9,200 Btu. Any additional rear burners to the right are
15,000 Btu.
SURFACE BURNERS
1
Remove the burner cap, then remove two screws
from each surface burner.
2
Gently lift each burner, then disconnect the ignitor
wire. Set burner assemblies aside.
3
For each 20,000 Btu (5.9 kW) burner, remove the
existing main orifice and replace with a new '208'
then remove the simmer orifice and replace with a
new '79' orifice.
For the 18,000 Btu (5.3 kW) burner, remove the
existing main orifice and replace with a new '205'
then remove the simmer orifice and replace with a
new '79' orifice.
For each 15,000 Btu (4.4 kW) burner, remove the
existing main orifice and replace with a new '180'
then remove the simmer orifice and replace with a
new '79' orifice.
For the 9,200 Btu (2.7 kW) burner, remove the
existing main orifice and replace with a new '140'
then remove the simmer orifice and replace with a
new '65' orifice.
Dual Fuel Range Conversion to Natural Gas
Installation
www.subzero-wolf.com 800.222.7820
829537 REV-A 04/2020
Page 1 of 3