Wolf Steel WSC43BA Installation Manual Download Page 1

W415-4094 / 06.10.22

INSTALLATION GUIDE 

WSC43BA Thermostat

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030

Phone 1 (866) 820-8686 • www.napoleon.com • [email protected]

Summary of Contents for WSC43BA

Page 1: ...094 06 10 22 INSTALLATION GUIDE WSC43BA Thermostat Wolf Steel Ltd 24 Napoleon Rd Barrie ON L4M 0G8 Canada 103 Miller Drive Crittenden Kentucky USA 41030 Phone 1 866 820 8686 www napoleon com hvac napoleon com ...

Page 2: ... to repair the unit on your own Do not expose the unit or its accessories to flammable liquids gases or other explosives Product Name Model Number FCC ID IC ID Touchscreen Thermostat WSC43BA VA8 WSC43BA 7114A WSC43BA Indoor PIR Temperature Sensor WSC IS VA8 WSC IS 7114A WSCIS Outdoor Temperature Sensor with Probe WSC OS Thermostat Power Module not included WSC PWRM N A This device complies with Pa...

Page 3: ...e Changes other than editorial are denoted by a vertical line in the margin 1 0 welcome 4 2 0 in the box 4 3 0 wiring diagrams 5 4 0 installation guide 8 4 1 removing your old thermostat 8 4 2 connecting the wires 11 4 2 1 install the thermostat with a C wire 12 4 2 2 install the thermostat without a C wire optional 16 5 0 FAQs 25 6 0 technical specifications 28 7 0 home app 31 8 0 meet your therm...

Page 4: ...mfort or select specific sensors for target temperatures You can also set schedules for your thermostat so it operates automatically based on the selected time periods and settings 2 0 in the box Label 1 Label 2 Thermostat If you have a C wire you will not need the label 2 below Control board C C RC RC RC RC RH RH R R C C S S G G R R RC RC RH RH Y2 Y2 Y Y1 Y Y1 Y Y1 Y Y1 W W1 W W1 W W1 W W1 W2 W2 ...

Page 5: ...P switch on the back of the thermostat to Disconnect if you have connected both RC wire and RH wire to the wall plate Otherwise switch it to the Connect side G S Y1 Y2 M1 M2 C RC RH O B W1 W2 Y1 Y2 C Y1 Y2 W1 W2 R C G Air conditioner Furnace For dual heat and cooling system if applicable Humidifier Dehumidifier optional Conventional Heating and Cooling System ...

Page 6: ... the DIP switch on the back of the thermostat to Disconnect if you have connected both RC wire and RH wire to the wall plate Otherwise switch it to the Connect side For dual heat and cooling system if applicable R O B W1 W2 O B Heat pump Air handler G S Y1 Y2 M1 M2 C RC RH O B W1 W2 Y1 Y2 C Y1 Y2 W1 W2 R C G Humidifier Dehumidifier optional ...

Page 7: ...e DIP switch on the back of the thermostat to Disconnect if you have connected both RC wire and RH wire to the wall plate Otherwise switch it to the Connect side G S Y1 Y2 M1 M2 C RC RH O B W1 W2 Y1 Y2 C Y1 Y2 W1 W2 R C G O B1 R Air conditioner or Heat pump Boiler Air handler For dual heat and cooling system if applicable 1 For heat pump only Humidifier Dehumidifier optional ...

Page 8: ...HVAC system to protect you and to avoid blowing a fuse Wait a few minutes then try to adjust the temperature of your old thermostat to verify that the system is off RC RH G C Y1 Y2 W1 W2 O B Do not remove the wallplate Old thermostat Breaker box Switch Step 2 Remove the old thermostat Remove the old thermostat from the wall Keep the wall plate with wires ...

Page 9: ...h wire nuts on the backplate of the old thermostat or if the voltage of your old system is 120V or higher it will not be compatible with WSC43BA If none of the above is true please proceed to the next step Step 4 Take a photo Take a photo of the wires connected to the terminal of your old thermostat You may need to reference this photo later ...

Page 10: ...then carefully disconnect the wires RC RH G C Y1 Y2 W1W2 O B C RC G W1 Y1 RC RH G C Y1 Y2 W1W2 O B C RC G W1 Y1 Remove NOTE If there are any jumper wires between Rh Rc or R terminals do not label them WSC43BA does not need jumpers Remove and save them along with your old thermostat NOTE For unique wiring situations see Wiring Diagrams section ...

Page 11: ... RH 24VAC primary for heating C 24VAC common W1 1st stage primary heating relay AUX heat W2 2nd stage secondary heating relay AUX heat Y1 1st stage primary compressor contactor Y2 2nd stage secondary compressor contactor G Fan relay O B Changeover valve for heat pumps S Optional wiring module terminal to combine Y and G while reserving an extra in wall wire to power on the thermostat RC RH G C Y1 ...

Page 12: ... C wire Step 1 Remove the wall plate Unscrew the wall plate from the wall then gently pull it out to ensure the wires will not fall back into the hole Step 2 Attach the base of WSC43BA to the wall Bundle and insert the wires through the holes of the base of WSC43BA then attach the base to the wall with screws supplied ...

Page 13: ...e corresponding terminal in the base Take a photo of the wires when you are finished You may need to refer to it later during the setup wizard Do you have more than one R wire R RC or RH YES R or RC wire into the RC terminal RH wire into the RH terminal NO R RC or RH wire into the RC terminal G S Y1 Y2 M1 M2 RC C RH O B W1 W2 W 1 R R C R H C G Y1 G S Y1 Y2 M1 M2 RC C RH O B W1 W2 W 1 R R C C G Y1 ...

Page 14: ...djust the DIP switch on the back of the thermostat to Disconnect if you have connected the RC wire and the RH wire to the wall plate Otherwise switch it to the Connect side Step 5 Attach the WSC43BA to the base Gently press the WSC43BA into the base until it clicks RC RH Connect Disconnect DIP switch ...

Page 15: ...r on your system Congratulations The installation is finished Please power on your HVAC system When the power is successfully energized the thermostat s screen will light up and go into the setup wizard You can complete the following configuration according to section 4 ...

Page 16: ...equires your system to have the following wires 4 wires W W1 Y Y1 G and R or Rc or Rh Or 3 wires Y Y1 G and R or Rc or Rh If you do not have these wires your system may not be compatible with the power module RC RH G C Y1 Y2 W1W2 O B RC G Y1 W1 RC RH G C Y1 Y2 W1W2 O B RC G Y1 W1 WSC PWRM Power Module Not Included ...

Page 17: ...system does not have a C wire you can use the power module to power your thermostat using the existing wires Power module To thermostat To HVAC control board There are two sides with connections One side 4 terminals is for thermostat connections the other side pre wired 5 terminals is for the control board connections ...

Page 18: ...tags provided label 2 control board W C G Y R W R G Y To thermostat W C G Y R W C G Y R Label 1 Label 2 Thermostat If you have a C wire you will not need the label 2 below Control board C C RC RC RC RC RH RH R R C C S S G G R R RC RC RH RH Y2 Y2 Y Y1 Y Y1 Y Y1 Y Y1 W W1 W W1 W W1 W W1 W2 W2 O B O B G G W C G Y R W R G Y To thermostat W C G Y R W C G Y R Label 1 Label 2 Thermostat If you have a C w...

Page 19: ...rom the control board Step 4 Connect the wiring module Reconnect them correspondingly to the 4 terminals side of the power module R RC W W1 W G C Y Y1 S R Y G W Control Board W R G Y W C G Y R To thermostat To thermostat Power module R Y G W Control Board W R G Y W C G Y R To thermostat To thermostat Power module ...

Page 20: ... terminals Step 6 Position the wiring module The power module should be installed between your thermostat wiring and your control board Install it in the right position then close the HVAC cover panel securely and return to your thermostat HVAC Control Board W C G Y R Power module R Y G W To HVAC control board To thermostat HVAC Control Board W C G Y R Power module R Y G W To HVAC control board To...

Page 21: ...2 W1W2 O B RC R C C G W1 Y1 S Label 1 Label 2 Thermostat If you have a C wire you will not need the label 2 below Control board C C RC RC RC RC RH RH R R C C S S G G R R RC RC RH RH Y2 Y2 Y Y1 Y Y1 Y Y1 Y Y1 W W1 W W1 W W1 W W1 W2 W2 O B O B G G RC RH G C Y1 Y2 W1W2 O B R C RC G C S W1 Y1 RC RH G C Y1 Y2 W1W2 O B RC R C C G W1 Y1 S Label 1 Label 2 Thermostat If you have a C wire you will not need ...

Page 22: ...o the wall with screws supplied Then connect other wires to the corresponding terminal in the base Take a photo of the wires when you are finished You may need to refer to it later during the setup wizard G S Y1 Y2 M1 M2 RC C RH O B W1 W2 RC R C G C W 1 Y1 S Step 10 Connect the wires First connect 3 wires as shown below RC C S G S Y1 Y2 M1 M2 RC C RH O B W1 W2 RC R C G C W 1 Y1 S ...

Page 23: ...11 DIP switch Adjust the DIP switch on the back of the thermostat to the Connect side Step 12 Attach the WSC43BA to the base Gently press the WSC43BA into the base until it clicks RC RH Connect Disconnect DIP switch RC RH Connect Disconnect DIP switch ...

Page 24: ...tem Congratulations The installation is finished Please power on your HVAC system Hi Wel com e When the power is successfully energized the thermostat s screen will light up and go into the setup wizard You can complete the following configuration according to section 4 ...

Page 25: ...rs while leaving the main body of the sensor indoors Make sure the sensor is within 10 meters of the thermostat You can set the indoor remote sensor as the main sensor or to only participate in the calculation of the average temperature Only one sensor can be set as the main sensor at a time With multiple indoor remote sensors if one of them is set as the main sensor the other indoor remote sensor...

Page 26: ...firm the entered router password is correct 5 If it still does not work it is recommended to reset the router and try again What if the device is offline 1 Confirm if the thermostat is powered on 2 Confirm if the device or the network has been cut off If so please reconnect the network as it may need some time to recover Please check the status 2 minutes later 3 Confirm that the network is stable ...

Page 27: ...device is still offline please check if there are too many WiFi connections Try restarting the router wait for 5 minutes and observe the status of the device 6 If it still does not work it is recommended to remove the device or reset the router and then add it again ...

Page 28: ... hot water steam or gravity gas fireplac es 24 volts oil heat sources heat pump dual fuel HVAC Control Functions System mode Heat Cool Auto Off Hybrid mode Low Cost Comfort Green Nighttime Fan mode On Auto Circle adjustable Advanced Setting temperature locally or remotely Auto changeover between heat and cool mode System Auto Compressor protection time is available for select equipment Failure pro...

Page 29: ...r touch screen PIR Sensor Sensing distance 3m angle 70 Electrical Rating 24 VAC 1A carry 5A surge 50 60 HZ Max Load Current 1A Operating Environment 0 C 50 C 32 F 122 F Humidity range 5 95 Storage Temperature 30 C 60 C 22 F 140 F Wiring 18 AWG requires both R and C wires from the HVAC system Dimensions 131mm L x 78mm W x 29 2mm H Mounting Type Wall mounting ...

Page 30: ...es Radio 915MHZ LED 2 color LED red green PIR Detect occupancy Sensing distance 5m angle 120 Operating Environment 0 C 50 C 32 F 122 F indoor only Humidity range 5 95 Dimensions 62mm L x 62mm W x 15 5mm H Mounting Type Wall mounted or placed on a stable surface i e a tabletop stand Connectivity Range 10m ...

Page 31: ...s By pairing your appliance to the Home App via WiFi you gain control to all modes and functions of the appliance All notifications and alarms are sent through the app to keep you connected with ease How Does It Work Let s Get Started Download the Home App from your app store Google Play or Apple App Store Note This requires Android 7 0 or iOS 11 0 1 2 Register an account with the Home App OR sign...

Page 32: ...4 The information entered in Step 3 will be registered to the Home App and a confirma tion will be sent to the email provided Open email inbox and select the confirmation link Note The confirmation link must be opened on the device that the Home App is installed on 5 Welcome If no email is found click Re Send Confirmation Link and check junk folder 6 ...

Page 33: ...pliance is plugged in and turned on 8 Select Add Device and accept the permissions 9 Search for devices and select the device from the list Your New Connect Product 10 Select your desired WiFi and connect by entering the WiFi password of your home Your Home Wifi SSID ...

Page 34: ...W415 4094 06 10 22 34 home app EN 11 Once the appliance has been connected to the access point it can be given a nickname for recognizability Your New Connect Product 12 You are now connected ...

Page 35: ...te Time Low Sensor Battery Icon Outdoor Temperature Humidity Status Indicator Control Access Indoor Humidity only when viewing temperature controls WiFi Increase Temperature Set Point Temperature Decrease Temperature System Mode Menu Hold Mode Fan Mode Indoor Temperature Weather Icon ...

Page 36: ...W415 4094 06 10 22 36 meet your thermostat EN System Mode Heat Heating only Cool Cooling only Auto Automatic control of heating and cooling based on ambient temperature Off Turn the system off ...

Page 37: ...lick the weather icon to display the real time outdoor weather condition and temperature for the current day in your home location Fan On Runs continuously Auto Automatically adjust fan according to the system mode Clr Runs at intervals to circulate air Fan Fan Fan ...

Page 38: ...ure control access for humidifying for dehumidifying Tap icon to switch between humidity and temperature views Outdoor humidity only when viewing humidity controls Increase humidity level if humidifier is connected Humidity level Decrease humidity level if dehumidifier is connected Indoor humidity ...

Page 39: ...the outdoor temperature is below this temperature the Heat Pump will not be used Max Heat Pump Run Time This is the length of time the Heat Pump is allowed to run Hybrid Choose your preferred source of heating from the options in Heat Source The thermostat will satisfy demand based on selections made The Hybrid selection will enable the use of dual fuel switching alternating between primary and se...

Page 40: ...Max Runtime adjustable and AUX Heat Stage 2 Temp Delta non adjustable in Menu Settings Installation Advanced setting Comfort Satisfy your heating demands with any available fuel source to prioritize your comfort levels always keeping your home as close to your desired set point as possible In this mode the second stage HP heating is will be turned When Hybrid heating is selected in Menu System Hea...

Page 41: ...cording to the Compressor Stage2 Temp Delta non adjustable and Compressor Stage1 Max Runtime adjustable and second stage furnace heating will be turned on according to Aux Heat Stage 1 Max Runtime adjustable and AUX Heat Stage 2 Temp Delta non adjustable in Menu Settings Installation Advanced setting Nighttime Run quiet operation of your unit at night limiting fan speed and utilizing low stage hea...

Page 42: ...llow Schedule Permanent Hold This will always hold the current target temperature fan or hybrid mode if enabled It will override the current schedule settings Temporary Hold Keep the current target temperature fan or hybrid mode if enabled until the next scheduled activity begins You can select this mode manually or by adjusting the target temperature fan or hybrid mode if enabled under Follow Sch...

Page 43: ...Menu Vacation You can set the time of departure and return as well as the highest and lowest temperatures during this period The thermostat will automatically hold this temperature range NOTE During this mode you cannot manually change the target temperature If you want to exit this mode change the Hold mode manually or delete the vacation in menu Vacation Mode ...

Page 44: ...and what they mean When you turn on the compressor frequently there will be a time countdown to protect the compressor This will occur in the following case Heat pump heating cooling Conventional cooling You can set the time countdown in Menu Installation Advanced Compressor Protect Time 1 2 ...

Page 45: ...connected to the router but the router is not connected to the network Unusual heating or cooling alert When the following occurs this prompt appears on the thermostat 1 When your thermostat is cooling the temperature in the room does not go down for a long time but instead the temperature still rises 2 When your thermostat is heating the temperature in the room does not go up for a long time but ...

Page 46: ...Fan Switch fan mode ON Auto Cir Weather Weather conditions of the real time in your home location Sensors Add multi sensors to balance the current temperature throughout the home Schedule Set schedule to change the temperature automatically Vacation Set vacation to change the temperature automatically ...

Page 47: ...g heating cooling cycles WiFi Configure and display WiFi information Smart Warm Up When smart warm up is enabled your thermostat automatically calculates when to turn on heating or cooling so your home will reach a scheduled temperature on time This only worked in Follow Schedule mode Device Name Rename your device Temp Unit Celsius or Fahrenheit Temp Range Set the adjustment range of heating and ...

Page 48: ...ry heat is turned on during heating cooling cycles 4 Aux Heat Stage 2 Temperature Delta When the difference between the indoor temperature and the target temperature reaches this value the second stage is automatically turned on 5 Aux Heat Stage 1 Max Routine If the first stage fails to reach the target temperature after this time the second stage will be automatically turned on 6 Hybrid Max Heat ...

Page 49: ...quipment Reconfigure your wiring setting on thermostat Equipment Test Test whether the corresponding function of the equipment can run normally as required Filter Filter change reminder Reset Reset setting Reset schedule Reset system schedule and clear vacation Reset all Reset the thermostat to default factory setting About Show device information ...

Page 50: ... the week so that you can get the right temperature at a certain time Humidity Control Displays the current humidity level Tap to adjust target level Set Point Temperature Increase decrease the target temperature Heating Mode Displays heating source selection When hybrid heating is selected options to select hybrid modes will be displayed Settings You can edit the app settings such as device name ...

Page 51: ...W415 4094 06 10 22 51 notes EN ...

Page 52: ... with minimum distance of 20cm the radiator your body This device and its antenna s must not be co located or operation in conjunction with any other antenna or transmitter IC warning This device contains licence exempt tasmittre s receiver s that comply with Innovation Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 this device...

Reviews: