11.4 Control settings parameter sheet
Pump unit no.:
Menu item
Possible
setting
Setting
Factory
setting
P1
Selection between time and pulse mode
Time 001
Pulse 002
1
P2
Cycle time setting in hours in time mode, lower row
of elements
0
… 255
0
P3
Cycle time setting in minutes in time mode, lower
row of elements
0
… 59
2
P4
External machine pulse setting in pulse mode,
lower row of elements
1
… 9999
5
P5
Pump delivery switch-off via the number of
distributor pulses, lower row of elements
On = 001
Off = 000
0
P6
Number of distributor pulses until pump delivery
switch-off, lower row of elements
1
… 999
0
P7
Distributor monitoring, lower row of elements
On = 001
Off = 000
0
P8
Delivery time setting in hours, lower row of
elements
0
… 100
0
P9
Delivery time setting in minutes, lower row of
elements
0
… 59
1
P10 Selection of stirring function, lower row of elements
Yes = 001
No = 000
0
P11
Off-duty time setting in hours between two stirring
processes
1
… 100
1
P12
Cycle time setting in hours in time mode, upper
row of elements
0
… 255
0
P13
Cycle time setting in minutes in time mode, upper
row of elements
0
… 59
2
P14
External machine pulse setting in pulse mode,
upper row of elements
1
… 9999
5
P15
Pump delivery switch-off via the number of
distributor pulses, upper row of elements
On = 001
Off = 000
0
P16
Number of distributor pulses until pump delivery
switch-off, upper row of elements
1
… 999
0
P17 Distributor monitoring, upper row of elements
On = 001
Off = 000
0
P18
Delivery time setting in hours, upper row of
elements
0
… 100
0
P19
Delivery time setting in minutes, upper row of
elements
0
… 59
1