GMG-K / GMG-L Operation manual
Page 28 of 58
B0793 / B0796
7. Operation
7.1 Control "C" (option)
The control serves to trigger and monitor the pump unit. It is capable of switching the pump
on and off depending on time and load. Furthermore, the control can be used to monitor the
filling level and functioning of the progressive distributors. In case of fault, a corresponding
message can be submitted to a superior system. The control needs to be started by way of
an external "release".
Control variant "C":
Without connections 8.1 and 8.2
for distributor monitoring
Control variant "C3":
With connections 8.1 and 8.2
for distributor monitoring
When voltage supply is switched on, the control displays "ON" or "OFF", where "ON"
indicates readiness for operation (external release = 24 V on Pin 2).
On the control, you can adjust various menu items and parameters. The meanings of the
various menu items are as follows:
CODE: Menu release
P1
Selection between time mode (001) and pulse mode (002)
Parameters for the lower element row or pump unit with one element row:
P2
Setting of cycle time in hours (0
… 255) in time mode
P3
Setting of cycle time in minutes (0
… 59) in time mode
P4
Setting of external machine pulses (1
… 9999) in pulse mode
P5
Pump delivery switch-off via number of distributor pulses
(ON = 001 / OFF = 000)
P6
Number of distributor pulses until pump delivery switch-off (1
… 999)
P7
Distributor monitoring ON = 001 / OFF = 000
P8
Setting of delivery time in hours (0
… 100)
P9
Setting of delivery time in minutes (0
… 59)
P10 Selection of stirring function (yes = 001/no = 000)
(for one pump element row only!)
P11 Setting of off-duty time between two stirring processes in hours (1
… 100)
(for one pump element row only!)