Manual_S5_Airplus_2015_04_20
Page 42 / 68
©
Wodtke GmbH - Tübingen. All Rights and Changes Reserved.Printed 04/2015
Part No. 950 976
16.1 Scope of Maintenance
Maintenance comprises the following actions,
which are described in detail in the following chap-
ters:
Expanded basic cleaning - cleaning of
burner pot, cast grate and ash chamber
(for scope, see Cleaning chapter)
with
additional actions
Cleaning of
heating gas flues
Cleaning of
flue gas fan and connector
Inspection and cleaning of
air volume
sensor and air intake
Inspection and cleaning of
electrical com-
ponents/contacts
Inspection and cleaning of
convection air
routing
Inspection and cleaning of
pellet chute
and TP sensor
Completion of maintenance work,
test run
and
maintenance reset
In addition to our special brushes enclosed with
the units, you will require the following for mainte-
nance:
Vacuum cleaner (we recommend our Ash
Box as the attachment)
Screwdriver (Phillips head), socket and
fork wrench set
Pliers
Paint brush
Do not perform maintenance work until the
unit is in Stand-By mode and the fan stop delay
has completed.
Tip:
place newspapers or the like in front of the
furnace before opening the doors, so that the flue
ash that falls from the doors lands on top of them.
Caution!
Embers remaining in the ash represent an acute
fire hazard. Only vacuum ash into a vacuum
cleaner bag if you are absolutely certain that
there are no more embers within it.
Attention / Warning:
Risk of fire, short-circuit and mortal injury
Operation of the unit is only permitted with all pan-
elling components properly assembled, as other-
wise the unit's approval as well as any warranty or
guarantee are void, because there is risk of con-
tacting electrically live or hot parts.
Disconnect the power plug before beginning
work and do not plug the power plug back in
for the test run and maintenance reset until all
panelling parts have been completely and
properly reassembled.