Servicing, cleaning, maintenance
Before clamping components with the zero point clamping system, it is important to ensure
that no fragments or other foreign bodies are in the system. This applies in particular to the
hole for the alignment bolt and the base plate, which must be clean.
7.1
Installation
Before installation, the thread and threaded hole in the spindle assembly should be
lubricated with KLÜBER MICROLUBER grease.
Turn the clamping screw
-d-
into the threaded plate
-f-
, adjust the distance between the
threaded plate and the thread recess to the dimension of 17.5 mm.
Turn the clamping bolt
-e-
in as far as possible (figure 1). Then turn back until the clamping
bolt is aligned with the Ø18 step. (figure 2)
Insert the spindle unit into the plate insert
-g-
and use the M8 cylinder screw
-c-
to screw
home with 20 Nm.
Return clamping screw
-d-
up to the stop and check the distance between the threaded
plate
-f-
and the thread recess of the clamping screw
-d-
. This dimension should be
between 16.5 mm and 18.5 mm (17.5 * theor).
Fit the O-ring
-h-
.
Figure 1
Figure 2
17.5 *