6.2.
Labeling
When the module is installed in the host device, the FCC ID label must be visible through a window on
the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a
second label must be placed on the outside of the final device that contains the following text:
Co tai s FCC ID:
NKRM14A2A
The grantee's FCC ID can be used only when all FCC compliance requirements are met
6.3.
Thermal considerations
Ambient operating temperature:
–
30 °C to +75 °C
Ambient storage temperature:
–
40 °C to +85 °C
The case temperature of module shielding cover must be < 85 °C when integrated to prevent damage.
Design points used to improve the thermal performance:
It is better to add a naked copper area onto M14A2A
’
s back side of the PCB. If the thermal
performance becomes a issue in the customer
’
s product, add thermal solutions for
improvement such as thermal padding or a heat sink.
It
’
s recommended to have a thermal pad or a heat sink on shielding cover to help transfer
heat.