Gearless Lift Machine
WSG-S2.4
Operating Instructions
Code
GM.8.003290.EN
Date
13.06.2016
Version
0.10
Page
12
Subject to changes without notice ! Subject to changes without notice !
EN
Measuring system ECN 413
Number of sine-cosine
periods per rotation:
2048
Operating voltage:
5 V
Data interface::
SSI or ENDAT
Measuring system Sendix 8.5873
Number of sine-cosine
periods per rotation:
2048
Operating voltage:
5 V
Data interface:
BISS
Core
Signal
white
0 V (Up)
brown
U
p
green
Clock +
yellow
Clock -
grey
DATA +
pink
DATA -
blue
SET
red
DIR
black
A +
violet
A -
grey-pink
B +
red-blue
B -
shield
shield
Pin
Signal
1
U
p
Sensor
11
5
6
7
13
9
8
10 16
17
15 14
12
2
1
4
3
4
0 V Sensor
7
U
p
8
Clock +
9
Clock -
10
0 V (U
p
)
11
inner shield
12
B +
13
B -
14
DATA +
15
A +
Pin contacts of flanged con -
nector socket (exterior)
16
A -
17
DATA -
4.2.3. Speed/Position measuring system
• The basic version of the lift machines is equipped with an sendix 8.5873 SineCosine encoder from Kübler
GmbH. The encoder is connected by cable (length: 10m) with open wire ends (no plug).
• Alternatively, the machines can be equipped with ECN 413 or ERN 487 encoders (from Heidenhain GmbH).
We can also provide other measuring systems on request.
• Use a shielded cable to connect the Heidenhain measuring systems to the inverter system. We recommend
the use of our cable sets, which can be supplied as an accessory.
Caution
The measuring system of WSG lift machines with a
synchronous motor (WSG) is matched to the associat ed
inverter. Do not change the adjustment, as this may
make it impossible to use the motor. On the measur-
ing system housing there is a label showing the "offset
angle" and the inverter type.
The offset angle depends on the inverter used.