3 x 4000
3 x 1330
3 x 550
3 x 250
-20°C
130°C
145°C
150°C
155°C
165°C
Gearless Lift Machine
WSG/WGG-29
Operating Instructions
Code
GM.8.002662.EN
Date
04.02.2019
Version
0.19
Page
11
Subject to changes without notice ! Subject to changes without notice !
EN
Short-circuiting the motor terminals
• The motor terminals of the synchronous lift machines, type WSG, can be short-circuited, if required, to brake
the lift machine faster.
• However, this is only permissible at speeds less than or equal to the rated speed of the respective motor.
PTC thermistors
The maximum operating voltage of the PTC thermis -
tors is not allowed to exceed 25 V DC
To achieve the maximum precision, the
measurement voltage per PTC thermistor must not
exceed 2.5 V DC.
Cable cross-section required:
The table on the right gives the
standard values
for
the current-carrying capacity of PVC cables at a
maximum ambient temperature of 40°C.
Temperature
R
e
si
st
a
n
ce
[
]
Cable cross-section
required
Permissible max.
motor current I
N
(S1)
6,0 mm
2
38 A
10,0 mm
2
53 A
16,0 mm
2
71 A
25,0 mm
2
94 A
35,0 mm
2
117 A
50,0 mm
2
146 A
70,0 mm
2
180 A
95,0 mm
2
217 A