Wittkopp Anchor 4000 Series Installer Manual Download Page 5

Anchor 4000 

Installer manual  

Installation and commissioning instructions  

en_A4000-Teil 2-Errichterhandbuch V2.03.docx 

5 / 7 

 

 
 
Tighten  up  the  fastening  screws  to  a 
maximum torque of 10 Nm. We recommend 
the use of a bolt locking agent (adhesive) to 
prevent the screws from coming undone by 
themselves.

 
 
The  bolt  of  the  lock  may  not  be  under 
tension or pressure after installation.

Wiring / installation 

If  the  lock  is  operated  outside  the  area  of 
validity  of  the  VdS,  then  signal  boxes, 
external  power  supplies,  etc.  can  be  used 
with the Anchor in addition to all the analog 

keypads  that  are  compatible  with  the 
Primor  series.  The  VdS  approval  is 
restricted to operation with input units of the 
Primor FS, FL, RO and RE series. 

 
 

 

 

Connection of an analog keypad 

As supplied, only the interface for an analog 
keypad from  the  Primor series  is  active.  If 
the  lock  is  to  communicate  with  a  digital 
input  unit,  i.e.,  an  "intelligent"  one,  then 
additional settings are required in the setup 
menu [6] in addition to the selection of the 
corresponding interface or socket.  

You can find the corresponding commands 
in the user manual.  
You  can  find  information  on  inserting  the 
battery  in  the  operating  manual  of  the 
corresponding Primor keypad.

.

 

 

 

analog keypad 

e.g.  Primor  RO 

serial interface [UART] or 

[IO] for Alarmbox 

Cut off the power supply, including that from batteries, before starting any work or making 

any changes to the wiring between the lock, keypad or signal boxes.   

 

Summary of Contents for Anchor 4000 Series

Page 1: ...neral 2 Preparation for installation 3 Installation dimensions 3 Preparation of the boltwork door 3 Installation 4 Wiring installation 5 Connection of an analog keypad 5 Connection P signal plus UART 6 Function test 6 Input of the opening code 6 Keypad test 7 System setup 7 Mount the keypad before installing the electronic lock All the keypads of the Primor series can be used Details on installing...

Page 2: ... the electronic lock in the area of the cutouts in the safe door It is essential that the lock is protected against attacks from outside We recommend that you protect against access the security relevant parts of the high security lock also when the door of the container that holds the valuables is open It is not permissible to use two locks of the same type in connection with analog keypads witho...

Page 3: ...on of the boltwork door For installation of the lock there must be three threaded holes with 5 mm screw in depth for attachment to the boltwork or within the safe door The electronic lock is to be attached with the supplied M6 or 1 4 screws or cylinder screws minimum strength class 8 8 The length of the screws must be 25 mm or more so that a minimum screw in depth of 5 mm is attained ...

Page 4: ...direction of the bolt without any play up to the edges of the strikers of the boltwork and tighten up the retaining screws The position must be selected such that the sliding striker of the boltwork runs over the entire opening path on the slanted sliding surfaces of the bolt and when fully open on the bolt head Tighten up the retaining screws so as to ensure a permanent and secure hold The screw ...

Page 5: ...e VdS approval is restricted to operation with input units of the Primor FS FL RO and RE series Connection of an analog keypad As supplied only the interface for an analog keypad from the Primor series is active If the lock is to communicate with a digital input unit i e an intelligent one then additional settings are required in the setup menu 6 in addition to the selection of the corresponding i...

Page 6: ...nction test after completing all the mounting and installation work With the door open you should open and close the lock several times using the master code that had been set at the factory The relationship between easy opening and reliable closing can be set via the operating lever of the boltwork The locking check can be done via the operating lever of the boltwork and should be performed after...

Page 7: ...s indicated by a long signal tone and the function test is terminated The system must be checked System setup The setting options and the control sequences that are required are described in the user manual We therefore recommend the following procedure Setup of the users menu 1 if applicable parameterisation of the inputs and outputs menu 6 if applicable setting up the Dualcode condition menu 6 i...

Reviews: