5 / 7
Tighten up the fastening screws to a
maximum torque of 10 Nm. We recommend
the use of a bolt locking agent (adhesive) to
prevent the screws from coming undone by
themselves.
The bolt of the lock may not be under
tension or pressure after installation.
Wiring / installation
If the lock is operated outside the area of
validity of the VdS, then signal boxes,
external power supplies, etc. can be used
with the Anchor in addition to all the analog
keypads that are compatible with the
Primor series. The VdS approval is
restricted to operation with input units of the
Primor FS, FL, RO and RE series.
Connection of an analog keypad
As supplied, only the interface for an analog
keypad from the Primor series is active. If
the lock is to communicate with a digital
input unit, i.e., an "intelligent" one, then
additional settings are required in the setup
menu [6] in addition to the selection of the
corresponding interface or socket.
You can find the corresponding commands
in the user manual.
You can find information on inserting the
battery in the operating manual of the
corresponding Primor keypad.
.
analog keypad
e.g. Primor RO
serial interface [UART] or
[IO] for Alarmbox
Cut off the power supply, including that from batteries, before starting any work or making
any changes to the wiring between the lock, keypad or signal boxes.