Hydraulic System
Before attempting to install the new pump, it is very important to check the port configuration on
that pump; the ports on the replacement pump must be positioned the same way as on the old
pump. If they are not, proceed with the indexing of the new pump.
The replacement pump must be oriented in such a way to facilitate reconnection to the hydraulic
system and attachment to the chassis frame.
N
OTE
:
Both sections of the pump are indexable: the body section and the arm section.
To index the new pump
, proceed this way:
12 a.
Put the pump on a flat surface or in a vise.
BODY SECTION
12 b.
Remove all 4 retaining bolts that hold the mounting cap in place.
N
OTE
:
You may leave two retaining bolts partially unscrewed to facilitate rotation with a metallic bar.