background image

Digital Wireless Weather Station

OPERATING INSTRUCTION

Base unit: WT2081

Wireless sensor: WT2039A

Remove the protective film from the display before use.

Summary of Contents for WT2039A

Page 1: ...Digital Wireless Weather Station OPERATING INSTRUCTION Base unit WT2081 Wireless sensor WT2039A Remove the protective film from the display before use ...

Page 2: ...st be disposed of and replaced by a switching adapter of the same type Danger from electricity when using the switching adapter Connect the device to a properly installed power socket with a voltage that corresponds to the Technical Data Ensure that the socket is easily accessible so that you can quickly remove the switching adapter if necessary Do not use the wireless weather station if the switc...

Page 3: ... display in C F Indoor and outdoor humidity display Outdoor temperature display in C F with up to three wireless sensors at different measurement sites delivery includes one wireless sensor Minimum maximum display for temperature and humidity Humidity and temperature trend display Weather forecast symbols Moon phase display Mold indicator Dew point display Heat index Low battery indicator Battery ...

Page 4: ...4 Base unit Back Operating elements and parts of the base unit 1 Operating buttons Button Display alarm time Activate settings mode Save changes to settings Button ...

Page 5: ...Display weather data from various wireless sensors channel 1 2 3 Reconnect wireless sensor connection 2 Loop for hanging 3 Switching adaptor port 4 Battery compartment 5 Fold out stand Wireless sensor 1 Current transmission channel 2 Radio frequency display 3 Humidity display 4 Temperature display 5 Button TX Speed up wireless transmission to the base unit manually 6 C F button Switch temperature ...

Page 6: ...e and screw it into place Do not use batteries that have a voltage that is too low only 1 2 V instead of 1 5 V This affects the accuracy of the measurements among other things If possible use alkaline batteries instead of zinc carbon batteries Alkaline batteries last longer particularly outside in low temperatures Using additional wireless sensors The weather station comes with one wireless sensor...

Page 7: ... compartment cover 2 Insert 2 LR03 AAA 1 5 V batteries facing in the direction indicated on the bottom of the battery compartment Make sure that the poles of the batteries are correct 3 Put the battery compartment cover back in place and close it 4 Wait several minutes The base unit needs this time to collect all the weather data Information The device will lose all information when switching it o...

Page 8: ...e wireless sensor is protected against moisture but must be protected against water e g rain General The base unit and wireless sensor exchange information over a radio frequency For this reason the location is important for the range of the wireless connection Note The maximum distance between the base station and wireless sensor is 328 ft 100 meters However this range is only possible in open ar...

Page 9: ...therwise there is a risk of electric shock You can put the base unit on the desk or hang it up It s better to put on the desk Wireless sensor Place or hang the wireless sensor in a place where it is protected from direct weather rain sun wind etc Suitable locations include e g under a porch or in a carport Display indicators Base unit Time function ...

Page 10: ... 6 Press to store the setting The alarm time is set and activated Switching the alarm on and off Use the button to switch the alarm on and off press once on the display A1 is activated press twice on the display A2 is activated press three times and on the display A1 and A2 is activated press four times and disappear A1 and A2 is deactivated Stopping the alarm You will be woken by the alarm at the...

Page 11: ... and wake you up again You can repeat this process multiple times Weather information Temperature and humidity 11 Indoor thermo hygro symbol 12 Temperature trend 13 Mold indicator 14 Dew point 15 Stored maximum and minimum values 16 Low battery indicator 17 Humidity trend 18 Humidity in percent 19 Temperature unit C or F 20 Temperature ...

Page 12: ... values since midnight Information The weather station also has a temperature alarm For more information about this see Temperature alarm section Weather trend For the temperature and humidity values measured by the base unit and the wireless sensor the trend is displayed in the form of an arrow Trend rising constant falling Temperature Humidity Weather forecast After setting up initially the weat...

Page 13: ...less sensor is in use For the temperature alarm the wireless sensor with the lowest sensor number is always analysed When the symbol for the weather forecast begins to flash and the air pressure falls this is a sign that the weather is getting worse e g due to an approaching storm front When the air pressure increases again the symbols display continuously again An arrow shows the weather tendency...

Page 14: ... the display If the dew point is above 140 F HH H will appear on the display Heat index display for outdoors The heat index HEAT on the display is comprised of the temperature and humidity and displays the perceived temperature The heat index can only be displayed when the outdoor temperature rises above 80 F Phases of the moon The phases of the moon displayed are automatically updated with the da...

Page 15: ...wered by the power mains you should still remove any empty batteries present from the base unit Make sure that the poles of the batteries are correct when inserting Clean the battery and device contacts if necessary before inserting Dispose of the old batteries in an environmentally manner Resetting the weather station If the base station appears to display incorrect values you should reset the we...

Page 16: ...r manually Press and hold the button on the base unit until the display for the weather information flashes Move the base unit closer to the sensor or vice versa The display is illegible the function is not clear or the values are clearly wrong Reset the weather station to the factory settings Cleaning 1 When operating using the power mains Remove the switching adapter plug from the base unit 2 Wi...

Page 17: ...or a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarant...