TPM
+
Appendix
Revision: 07
4022-D018396
en-41
9.4.21 Technical specifications brake TPM
+
dynamic
The listed opening and closing times are noted without the use of an additional wiring of the brake.
To avoid interfering signals from the switching of the brake, in general an additional wiring, e.g.
in form of a varistor, should be added. Observe the requirements for this of the applied servo
controller manufacturer.
9.4.22 Technical specifications brake TPM
+
high torque
The listed opening and closing times are noted without the use of an additional wiring of the brake.
To avoid interfering signals from the switching of the brake, in general an additional wiring, e.g.
in form of a varistor, should be added. Observe the requirements for this of the applied servo
controller manufacturer.
Ordering code: TPM xxxx-xxxx-xxBx-xxxx-xx-xxx
Unit
TPM
+
004 TPM
+
010 TPM
+
025 TPM
+
050 TPM
+
110
Voltage
V DC
24
24
24
24
24
Power
consumption
A DC
0.42
0.42
0.58
0.71
0.71
Holding torque at
120
C
Nm
1.1
1.1
4.5
13
13
Opening time
msec
11
11
30
42
42
Closing time
msec
10
10
20
20
20
Tbl-37: Technical specifications brake TPM
+
dynamic
Ordering code: TPMAxxxx-xxxx-xxBx-xxxx-xx-xxx
Unit
TPM
+
010
TPM
+
025
TPM
+
050
TPM
+
110
Ratio i
22 –
110
154 –
220
22 –55
66 –
220
22 –55
66 –
220
22 –
88
110 –
220
Voltage
V DC
24
24
24
24
24
24
24
24
Power
consumption
A DC
0.58
0.46
0.71
0.58
1.0
0.71
1.67
1.0
Holding
torque at 120
C
Nm
4.5
1.8
13
4.5
23
13
72
23
Opening time
msec
30
30
42
30
50
42
200
50
Closing time
msec
20
25
20
20
40
20
50
40
Tbl-38: Technical specifications brake TPM
+
high torque
Summary of Contents for TPM dynamic
Page 1: ...4022 D018396 07 4022 D018396 Revision 07 TPM dynamic high torque power Operating Manual ...
Page 44: ...Appendix TPM en 44 4022 D018396 Revision 07 Option N and K signal pin assignment 1 ...
Page 45: ...TPM Appendix Revision 07 4022 D018396 en 45 Option S and M signal pin assignment 1 ...