LUC
+
125, 24 V, time-controlled
Revision: 01
1000088471
en-13
-
The lubricator is time-controlled and works time-based via the integrated microelectronics and
must be connected to a 24 V DC power supply. The lubricator cyclically delivers a defined
volume of lubricant from the cartridge to the outlet.
-
The relubrication volume is defined in months by the emptying time setting of the cartridge.
Emptying times
t
of 1...36 month(s) and a number of cycles
c
of 1…10 can be set.
-
The single-use changeable cartridges with a lubricant capacity of 125/250 cm3 ensure
controlled and consistent quality of lubricants and are filled without any trapped air. The
lubricator offers a reliable supply to lubrication points and prevents downtime of machinery.
This version of the lubricator is designed for grease lubricants.
-
The lubricator
cannot
be used without an external 24 V DC power supply. The lubricant
cartridge is included in the scope of delivery and already installed in the lubricator.
-
The respective modes of the lubricator are shown on the display, which also enables
recognition of the status by LEDs in different colors.
-
The use of cartridges of a different size requires consultation with
WITTENSTEIN alpha
GmbH
.
-
In case of any questions regarding your applications and the correct settings for the lubricator,
please contact
WITTENSTEIN alpha GmbH
.
6.1.2
Factory settings
Parameter
Program menu
Designation
Factory settings
Result
t
Emptying time
6
6 months
c
Number of cycles
2
2 pump strokes per
lubrication
(0.15 cm
3
/stroke)
Tbl - 5 Factory settings program menu
Parameter
Designation
Factory settings
Result
P
Maximum pressure
50
50 bar
Pu
Control mode
0
Time control active
U
Cartridge size
12
Cartridge 125 cm
3
E
Inverted output signals
1
Permanent high signal in
case of error
L
Empty cartridge signal
1
Permanent high signal in
case of error
F
Feedback signal
0
Low signal when motor is
running
Parameters P, Pu, U, E, L and F may only be changed after consultation.
If you have any questions, please contact WITTENSTEIN alpha GmbH Sales /
Customer Service.
Tbl - 6 Advanced programming factory settings