Test mode
Additional information
Standard
Mode for watches with Swiss anchor escapement.
To determine the amplitude of the watch, the lift
angle must be set.
Rate
Mode for rate measurement of watches with cyl-
inder, duplex or chronometer escapement, in addi-
tion to watches with unusual beat noise.
Special 1 (co-axial)
Mode for watches with co-axial escapement.
Special 2 (AP)
Mode for watches with AP escapement.
Determining the escapement type
You can find out the escapement type of the watch
that is to be tested by consulting the watch manu-
facturer.
The Watch Expert provides two different display modes in which
various parameters are measured and displayed.
Appearance
Function
Diagram
n
Shows the rate deviation, the beat error and the
amplitude.
n
During the measuring procedure, the measured
values are displayed as a diagram.
n
It is possible to configure the diagram view.
n
The 6 position windows show the diagram as it
relates to the respective measuring position.
n
If the measuring procedure has stopped, the meas-
ured values and the diagram can be shown in the
large display by tapping the small position windows.
VARIO
Visualises the rate stability and amplitude over a longer
period.
During the measuring procedure, the current measured
values, including the mean, are shown over the entire
measuring period, in addition to the minimum and max-
imum rate and amplitude values.
Overview of display modes
Product description
Modes
27.02.2018
Precision measuring device Watch ...