Reuleaux RX75 Overview
Specification & Features
Size:
87*22.5*47mm
Thread Type:
510 spring loaded thread
Cell type:
High-rate 18650 cell (discharging current should be above 25A)
Output Mode:
VW/Bypass/TC-Ni/TC-Ti/TC-SS/TCR Mode
Output Wattage:
1-75W
Resistance Range:
0.05-1.5ohm for TC modes
0.1-3.5ohm for VW/ Bypass mode
Temperature Range:
100-315°C/ 200-600°F (TC modes)
How to use:
1. Power on/off:
Unplug the magnetic back cover and put one 18650 cell into the battery body.
Press the fire button 5 times in quick succession to turn the device on and off.
(
Note:
Please adjust the wattage to a proper range to match the atomizer you used before using.
User Manual
75
English
1
English
2
English
3
English
4
English
5
English
6
English
7
English
8
English
9
English
10
English
11
English
12
Safety lock switch
510 spring connector
Front cover
OLED screen
Fire button/Back cover
Regulatory button
Micro USB port
Moreover, please be careful not to use battery with torn shell for safety.)
2. The operation of regulatory buttons:
Before doing related
regulation operation, you should open the front cover firstly.
3. Stealth function:
While the device is on, simultaneously hold the fire
button and the left regulatory button. This will switch the screen display
on and off.
4. Key lock function:
While the device is on, simultaneously press the
two regulatory buttons. This will switch between Key Lock and Key
Unlock function.
5. Safety lock switch:
Move the lock switch right/left to lock/unlock the
fire button so that unintentional press could be avoided.
6. Micro USB Port function:
The USB port can be used for charging and
upgrading firmware. It is better to take out the cell and charge it through
external charger.
7. Switch the display mode
: By pressing the left and right regulatory
buttons simultaneously in shutdown state, the screen display will rotate
180 degrees. You can then view the screen from two kinds of angle
through this operation.
Shift among VW/Bypass/TC-Ni/TC-Ti/TC-SS/TCR Mode
1.Press the fire button 3 times to enter the menu.
The OLED screen presents 5 rows of information:
(1). Power (VW), BP(Bypass), Temp Ni (TC-Ni), Temp Ti (TC-Ti), Temp SS(TC-SS) and TCR.
(2). Temperature: 100-315°C/ 200-600°F.
(3). Output wattage and Resistance in TC modes or Voltage and Resistance in VW/Bypass mode.
(4). User information (Puff: total vapor puffs, Time: total vaping time, PCB: the temperature of Printed
Circuit Board) and Current
(5). Battery indicator
2. After pressing the fire button 3 times, the first row will flash to indicate you enter into the menu.
Press the right regulatory button to switch between VW, Bypass, TC-Ni, TC-Ti, TC-SS and TCR
mode. Press the fire button, or leave the display to flash 10 times on the current setting to confirm
and exit the menu.
VW Mode:
In this mode, output wattage can be adjusted from 1W to 75W by pressing the regulatory buttons,
right to increase and left to decrease.
Bypass Mode:
Bypass mode is a direct output mode of voltage. In this mode, the internal chip is “bypassed” and the
supporting atomizer resistance is 0.1-3.5ohm.
TC-SS Mode:
The TC-SS mode is suitable to SS316 coil.
TCR (M1, M2, M3):
In TCR (Temperature Coefficient of Resistance) mode, users can set the
parameters according to the TCR of coil.
Under TCR mode, when the mode indication flashing, press the left regulatory button and then the
sub-menu items (M1, M2, M3) will flash. Press the right regulatory button to choose mode among
M1, M2 and M3 and then press the fire button to confirm.
The Setting of TCR Mode:
In powered-off state, keep pressing the fire button and
right regulatory button simultaneously, then you enter into the TCR set menu:
(1). Press the left or right regulatory button to choose among TCR M1, M2 and M3;
(2). Press the fire button to confirm the mode you chosen;
(3). Press the left or right regulatory button to increase or decrease the parameter
according to the TCR of coil;
(4). Keep pressing the fire button or leave the interface for about 10 seconds to confirm.
Following is the TCR value range of Reuleaux RX75 for your reference:
Note:
1. The TCR value in the sheet is 10 multiplied of the actual TCR.
2. The TCR value range for Reuleaux RX75 is 1-1000.
Supplementary TC Modes Functions:
Temperature adjustment:
In TC modes, the temperature can be adjusted from (100-315°C or
200-600˚F) with the two regulatory buttons, right to increase and left to decrease.
Shift between °C and ˚F:
If you increase the temperature to 315 °C, and continue to press the right
regulatory button, the temperature readings will automatically change to the lowest Fahrenheit
(200˚F). Equally, if the temperature is decreased below the minimum (100°C), the unit will change
back to ˚F automatically, and the temperature will start to decrease from 600 ˚F.
Wattage adjustment:
Press the fire button 3 times in quick succession to enter the menu. Press the
left regulatory button, and the wattage sign will blink. Then press the right regulatory button to adjust
the wattage, and press fire button to confirm. Long pressing the right regulatory button will make the
wattage setting rapidly increase.
Resistance locked function:
Press the fire button three times and enter into the menu. Press the
left regulatory button 2 times, and the resistance sign will blink. Press the right regulatory button to
lock or unlock the resistance of the atomizer. (
Note:
Such operation should be carried out at room
temperature.)
New atomizer installation:
In TC mode, be careful to attach new atomizers that have
cooled to room temperature. If a new atomizer has not cooled down before attaching,
the temperature may read and protect incorrectly until the new atomizer cools.
Note:
1. When you connect a new atomizer or disconnect and reconnect your existing
atomizer, the device will prompt you to confirm this change and a message will prompt
“New Coil Right, Same Coil Left”. Press the right regulatory button to confirm that a
new atomizer has been attached. Press the left regulatory button to confirm that the
same atomizer has been reconnected.
2. When using normal coil or the resistance of coil you used is higher than 1.5ohm in
TC modes, the device will automatically switch to VW mode.
Shift among Puff, Time and PCB:
Press the fire button 3 times to enter the menu. Press the left regulatory button 3
English
13
English
14
Nickel
NiFe
Titanium
SS (303, 304, 316, 317)
600-700
300-400
300-400
80-200
Material
TCR value range
5
times, and the user information row will blink. Now press the right regulatory button to shift among
Puff, Time and PCB (the temperature of Printed Circuit Board). (
Note:
The temperature unit of PCB
is consistent with that of temperature you set in TC modes.)
Display of current:
The sign shows the working current while you are vaping.
Malfunction Indication and Protection:
No Atomizer Alert:
When the device does not detect an atomizer, the OLED screen will display
“No Atomizer Found”.
Atomizer Low Alert:
When the resistance of atomizer is lower
than 0.1ohm in VW/Bypass mode or lower than 0.05ohm in TC
modes, the OLED screen will display “Atomizer Low”.
Atomizer Short-circuit Protection:
When atomizer
short-circuit occurs, the OLED Screen will display “Atomizer
Short”.
Temperature Alert:
If the internal temperature of the device is over 70°C, the output will shut off
automatically and the screen will display “Device Too Hot”.
Over 10 Second Protection:
When the power button is pressed for over 10 seconds, the output
will shut off and the OLED screen will display “Over 10s protection”.
Temperature Protection:
In TC modes, if the actual temperature of coil reaches the set
temperature, the device shows “Temp Protection”.
Weak Battery Alert:
In VW/Bypass/TC mode, when
the device installed with an atomizer is working and
the voltage of battery is below 2.9V, the device
shows “Weak Battery”. Meanwhile, the output power
will be reduced accordingly.
Low Power Alert:
If the power of battery is lower
Designed by
Inspired by VWT420
Manufactured by WISMEC
than 10%, the power symbol on the screen will flash.
Warning
1. Keep out of reach of children.
2. This device is not recommended for use by young people or non-smokers.