3.2
Changing IP address – directly connection to the module
If you want to connect directly to module without managing via GT11-control, you can change the IP
address under Mx-GT31
SETTINGS
NETWORKING
Internal Port.
4
Important information and maintenance
4.1
Operating System notes
The ventilation is important to prevent the overheating of the Tangram.
Ensure that the ventilation-ways are free.
Ensure that there is free space at the rear side.
Ensure that the guide rail not cover the ventilation ways.
Operation of the Tangram is only allowed while the fans are running.
The Tangram module includes a temperature-sensor, so if it is too hot for the Tangram module,
it stops running without a warning signal.
If the fan-unit is running, the DC-power unit works correctly
Condition
Limits
Permissible operating temperature inside
-5…+45 °C (ETSI EN 300 019-1-3 Class 3.1)
Recommend operation range of
+15…+35 °C
Humidty
Up to 95%, non-condensing
4.2
Article Numbers – Spare Parts
HW Name
Description
Number
GT31W
Frontend DVB-S/S2/C/T – IP Gateway
73291
5
Service and Support
For further information and help, please contact our support organization.
WISI Communications
WISI Norden AB
E-mail:
E-mail:
Telephone:
+49 7233 66-621
Telephone:
+46 13 21 09 15
E-mails sent to the above e-mail address will be available to all support staff.
Visit
for more information about configuration, Software, Entitlements and
Product information.
Te
chn
ic
al
M
o
di
fi
cat
io
ns
r
es
er
ve
d. WI
SI c
an
no
t b
e h
el
d
liab
le
f
o
r a
n
y p
ri
nt
ing
e
rr
o
r. 412
xxxx
/ 0
6
.14
WISI Communications GmbH & Co. KG
Empfangs- und Verteiltechnik
Wilhelm-Sihn-Strasse 5-7
Inland: Phone +49 7233-66-0 Fax -320
75223 Niefern-Öschelbronn
Export: Phone +49 7233-66-280 Fax -320
Germany
Email: