Dismantling:
All repairs of explosion-proof equipment must be made according the specified criteria of
IEC/EN 60079-19 rule by qualified personnel, having knowledge concerning electrical
equipment for potentially explosive areas containing gas and/or dust. Qualified personnel must
have knowledge regarding the types of explosion protection.
Maintenance:
The maintenance must be realized in accordance with IEC/EN 60079-17 and/or in accordance
with the national requirements.
Cleaning lens-
Washdown lens with water first to avoid partials scratching the surface. Clean
lens with damp microfiber cloth with mild dish soap and water. Lastly, apply coating of Repel (by
Unelko corporation) surface cleaner. Never use harsh chemicals or abrasive towels.
Replacing the battery- The Hanwha product has had the battery removed and affects the
operation of the RTC.
It is recommended to configure the NTP
setting to ensure the clock is correct.
For support please email [email protected]
DISMANTLING & MAINTENANCE