background image

HT-SPMA-SD

 P

ole Mount Adapter

HARDWARE 

QTY 4 7/8-20 18-8 Bolts

QTY 2 12in all thread with nuts and washers

QTY 2 A1612 sides

23

Summary of Contents for TNO-X6072EPT1-Z

Page 1: ...TNO X6072EPT1 Z TNO X8072EPT1 Z TNO X6322EPT1 Z Explosion Proof Network Camera Installation Manual ...

Page 2: ...marks have been appropriately capitalized Spectrum Camera Solutions LLC acknowledges all trademark s and the rights of the trademark s owned by the company referred to herein Release Date 02 10 2020 Document Name TNO XnnnnEPT1 Z INSTALLATION MANUAL Copyright 2020 by Spectrum Camera Solutions LLC Hanwha Techwin America All rights reserved Revision Record Rev Description Date 0 Initial Release 02 10...

Page 3: ...ver Page LEGAL NOTICES DESCRIPTION 4 LABELS 5 STANDARDS AND CERTIFICATIONS 6 DOCUMENT SYMBOLS 7 HOW TO USE THIS MANUAL 8 GENERAL SAFETY AND OPERATING INFORMATION 9 SPECIFICATIONS 12 UNBOXING HARDWARE 14 WIRING ENTRIES 16 INSTALLATION 17 DISMANTLING AND MAINTENANCE 21 3 ...

Page 4: ...mer Spectrum Camera Solutions LLC Hanwha Techwin America makes no representations or warranties with respect to the contents hereof Further Spectrum Camera Solutions LLC Hanwha Techwin America reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such revision or changes Patent Notice Manufactured under Un...

Page 5: ...Labels 5 ...

Page 6: ...sional information on the flameproof joints is necessary Follow the manufacturer s instructions to reduce the potential of an electrostatic charging hazard on the surface of the equipment in Group II and III environments NOTE Use a clean cloth dampened with pure water for cleaning CERTIFICATIONS CERT NO FM18US0262X FM18CA0126X US Class I Division 1 Groups BCD T6 Ta 40 C to 55 C Type 4X IP66 Class ...

Page 7: ... or equipment damage CAUTION Risk of electric shock or high temperature parts may result in injury if proper precautions are not taken NOTE Emphasizes important or essential information Locating Information NOTE In the interest of completeness manuals and drawings included with the system may provide information pertaining to options not included with your equipment Information in application note...

Page 8: ...l ATEX CSA IECEx NEC NFPA and FM certificates for any Special Conditions of Use If the sign X is placed after the certificate number it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule of the certificate NOTE Review all material and safety information in this manual and install in accordance with this document and all other a...

Page 9: ...all warranties and hazardous area certification s if unauthorized repair occurs General Precautions Slip resistant gloves and protective eyewear glasses with side shields or goggles as appropriate should be worn when installing and servicing any part of electrical equipment Hot components should be allowed to cool before servicing if possible Other appropriate equipment or clothing must be used as...

Page 10: ...ched securely and appropriately to a wall or supporting structure CAUTION The electrical cover should never be removed unless power is removed for at least 5 minutes from the unit or the area is known not to contain hazardous gases WARNING The product shall be installed by a trained professional The product shall be used in compliance with local laws and regulations Store the product in a dry and ...

Page 11: ...t be made in order not to alter the specific properties of terminal housing compartment The connection to the external circuits must be realized by cable glands or pipe fittings covered by a separate certificate s If a cable gland is not used or an entry is open the entry must be closed by a stopping plug covered by a separate certificate The diameter of the cable gland is inch NPT This equipment ...

Page 12: ...0 C to 55 C Type 4X IP66 Class I Zone 1 AEx Ex db IIB H2 T5 Gb Ta 50 C to 55 C Type 4X IP66 Zone 21 AEx Ex tb IIIC T85 C Db Ta 50 C to 55 C Type 4X IP66 II 2 G Ex db IIB H2 T5 Gb Ta 50 C to 55 C IP66 II 2 D Ex tb IIIC T85 C Db Ta 50 C to 55 C IP66 CERT NO FM18ATEX0073X IECEx FMG 18 0029X ELECTRICAL REQUIREMENTS of Model TNO X6072EPT1 Z POWER INPUT CONSUMPTION Camera IEEE 802 3af Type 3 7 5W Heatin...

Page 13: ...ow Voltage SELV according to clause 2 2 of IEC EN UL 60950 1 and Limited Power Source LPS according to clause 2 5 of IEC EN UL 60950 1 or CEC NEC Class 2 source of supply as defined in the Canadian Electrical Code CSA C22 1 and National Electrical Code ANSI NFPA 70 Class 1 electrical energy source ES1 and Class 2 power source PS2 rated output power limited to 100 W according to IEC EN UL 62368 1 W...

Page 14: ...14 UNBOXING ...

Page 15: ...50 20 HEX SCREW 4 1 SET SPLIT LOCK WASHER 5 HT F1XX WM WALL MOUNT NOT INCLUDED 6 QTY 2 SUN SHIELD STOP 7 1 SET 3125 18 PAN HEAD SCREW 8 1 SET LOCK WASHER 9 QTY 1 CMP 781DT25 BREATHER DRAIN OPTIONAL 10 QTY 1 R1 3 4 20 N NPT to M20 EX reducer 1 6 3 5 8 4 7 2 9 15 HARDWARE ...

Page 16: ...WIRING ENTRIES Conduit Entries are inch NPT Use appropriate adapter to keep ingress protection CAUTION Ensure power is disconnected prior to connecting NPT PORT NPT PORT 16 ...

Page 17: ...sunshield from the camera housing Tabletop Figure 2 1 Figure 2 1 17 Set screw 20 hex screws Figure 2 2 If wall mounted remove sunshield stop 3 Unscrew end cap from housing revealing terminal blocks and the rear of the camera The style of the camera may vary from that shown ...

Page 18: ...INSTALLATION Figure 4 4 Push release on terminal block and insert positive 12 28vdc connection into terminal block A release to secure Do the same for negative dc connection into terminal block B B A 18 ...

Page 19: ...the back of the Camera 5 2 Internal grounding screw 5850 6 SLBHUC 10 24x ZS ZGR INSTALLATION 19 Figure 5 1 Shielded RJ 45 Plug for STP cable Figure 5 2 6 Connect external ground For U S zones the internal grounding connection shall be used and the external grounding connection shall be a supplemental ground connection External ground wire connection is suitable for up to 3 25 mm 8AWG Figure 6 ...

Page 20: ...10 Install HT F1XX WM wall mount optional accessory 11 Remove Protective film after installation If protective film is not removed in timely manor damage to lens is likely to occur with UV exposure 12 Apply power For internal equipment startup procedures setting changes and troubleshooting guides reference the Hanwha camera manual included with the TNO XnnnnEPT1 Z Series Cameras If the included co...

Page 21: ...th IEC EN 60079 17 and or in accordance with the national requirements Cleaning lens Washdown lens with water first to avoid partials scratching the surface Clean lens with damp microfiber cloth with mild dish soap and water Lastly apply coating of Repel by Unelko corporation surface cleaner Never use harsh chemicals or abrasive towels Replacing the battery The Hanwha product has had the battery r...

Page 22: ...HT F1XX WM Wall Mount 22 ...

Page 23: ...HT SPMA SD Pole Mount Adapter HARDWARE QTY 4 7 8 20 18 8 Bolts QTY 2 12in all thread with nuts and washers QTY 2 A1612 sides 23 ...

Page 24: ...HT SD CM Corner Mount HARDWARE QTY 4 7 8 20 18 8 Bolts 24 ...

Page 25: ...SD VM Vibration Mount HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT 25 ...

Page 26: ...SD SO Standoff Mount HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT BACK 26 ...

Page 27: ...Accessory Mounting Diagram HT F1XX WM HT SD PMA HT F1XX WM SD VM SD SO HT SD PMA 27 ...

Page 28: ...Hanwha Techwin America 500 Frank W Burr Blvd Suite 43 Teaneck NJ 07666 Toll Free 1 877 213 1222 Direct 1 201 325 6920 Fax 1 201 373 0124 www hanwhasecurity com ...

Reviews: