9
ACW-DINDxxx_UG_EN_V1.8
b.
Electrical features
Min.
Type
Max.
Power supply (V)
10V
30V
Emission consumption (mA)
Condition:
-12V Power supply
-Every output is shut down
60mA
–
Sigfox
60mA
–
LoRaWAN
Condition:
- 24V Power supply
-Every output is shut down
35 mA
–
Sigfox
30mA
–
LoRaWAN
Reception consumption (mA)
Condition:
-12V Power supply
-Every output is shut down
50mA
–
Sigfox
30mA
–
LoRaWAN
Condition:
- 24V Power supply
-Every output is shut down
30mA
–
Sigfox
20mA
–
LoRaWAN
Standby consumption (mA)
Condition:
-12V Power supply
-Every output is shut down
20 mA
–
Sigfox
N/A
–
LoRaWAN
Condition:
- 24V Power supply
-Every output is shut down
15 mA
–
Sigfox
N/A
–
LoRaWAN
Input high level voltage (V)
2.8V
with Pull-Down
30V
(recommended)
2.3V
with Pull-Up
Input low level voltage (V)
0V
with Pull-Down
1.3V
with Pull-Up
0.15V
Dry contacts tensions of outputs
(V)
10V
Power supply tension
30V
Dry contacts outputs current (mA)
250 mA