October 2015

 

 
 

 

 

 

 

 

WaveIP Ltd. 

Teradion Industrial Park 

Misgav 20179, Israel 

Tel:  972-4-902-7000 

Fax: 972-4-999-0324 

[email protected]

 

The information contained in this document is of commercial value, 

proprietary to WaveIP. It is conveyed to the recipient solely for the 

purpose of evaluation. Reproduction of this document, disclosure of its 

contents or any other use of the information herein is strictly forbidden 

unless expressly authorized in writing by WaveIP. 

Summary of Contents for 8000

Page 1: ...gav 20179 Israel Tel 972 4 902 7000 Fax 972 4 999 0324 Info waveip com The information contained in this document is of commercial value proprietary to WaveIP It is conveyed to the recipient solely for the purpose of evaluation Reproduction of this document disclosure of its contents or any other use of the information herein is strictly forbidden unless expressly authorized in writing by WaveIP ...

Page 2: ...States or where FCC rules apply only those antennas certified with the product are used The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15 204 IMPORTANT Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and wherever applic...

Page 3: ...the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact WaveIP Warranty WaveIP warrants that this product shall be free from defects in workmanship and materials for a period of one year from the date of orig...

Page 4: ...ng 16 2 3 6 Cables 17 2 3 7 Indoor outlet installation 19 2 3 8 Grounding 20 2 4 CONSECUTIVE AP CONNECTION 21 2 5 SYNCHRONIZATION 22 3 WIPAIR 8000 TECHNICAL SPECIFICATIONS 23 3 1 RADIO 23 3 2 NETWORKING AND MANAGEMENT 23 3 3 PHYSICAL AND ENVIRONMENTAL 23 4 APPENDIX A OUTDOOR CABLES SCHEME 24 5 APPENDIX B RF CHANNEL LISTS 25 5 1 FCC OPERATING BAND 5725 MHZ 5850 MHZ 25 5 2 FCC OPERATING BAND 4940 MH...

Page 5: ...mbly to Outdoor Unit 18 Figure 2 7 Cable insertion to Outdoor Unit 18 Figure 2 8 Cable connection to Outdoor Unit 18 Figure 2 9 WipAir 8000 PoE 19 Figure 2 10 Ground Connection to Outdoor Unit 20 Figure 2 11 Consecutive link principle 21 Figure 2 12 External time synchronization 22 Figure 2 13 Internal time synchronization 22 Figure 4 1 Outdoor Cables Scheme 24 Figure 5 1 FCC 5 GHz RF channel List...

Page 6: ...ir r a ap pp pl li ic ca at ti io on ns s Point to Point PTP The basic subsystem is composed of a Master Unit MU and a Slave Unit SU Typical applications IP data backhaul of o WiMAX LTE operators o Metro WiFi Networks o Cellular and 3G Video surveillance networks Multi hop solutions Point to Multipoint PTMP The basic subsystem is composed of one Master Unit MU and multiple Slave Units SUs Typical ...

Page 7: ... Indoor PoE power supply indoor outlet 3 Pole mounting kit will not be added if advanced mounting kit is provided Figure 2 1 General System View 2 2 2 2 A Ad dd di it ti io on na al l p pa ar rt t l li is st t r re eq qu ui ir re ed d f fo or r i in ns st ta al ll la at ti io on n Outdoor Unit grounding cable Outdoor to Indoor shielded CAT5 cable up to 100 meters Indoor CAT5 cable RJ 45 Installati...

Page 8: ...Failure to do so may void the product warranty and may expose the end user or the service provider to legal and financial liabilities WaveIP and its resellers or distributors of this equipment are not liable for injury damage or violation of regulations associated with the installation of outdoor units or antennas Typical installation scheme Figure 2 2 WipAir General Installation Scheme Installati...

Page 9: ... The line between two antenna sites is an imaginary straight line which may be drawn between the two antennas Any obstacles in the path of the line degrade the propagation path The best propagation path is therefore a clear line of sight with good clearance between the line and any physical obstacle Physical obstacles Any physical object in the path between MU and SU may cause signal attenuation C...

Page 10: ...l mount is given in Figure 2 3 Figure 2 3 Wall mount WipAir advanced mounting kit features Azimuth and Elevation Adjustable Mount Suitable for pole or wall mounting Made of Die Cast Aluminum Heavy duty Figure 2 4 WipAir advanced mounting kit Note all outdoor units must be installed with a separation distance of at least 2 5 meters from all persons during normal operation ...

Page 11: ...he unit defines the frequency band supported by the units FCC 2 5GHz 4 9GHz 5 8 GHz ETSI 3 x GHz 5 4 GHz and 5 8 GHz Mexico 4 95 4 99 GHz 5 15 5 35 GHz 5 8 GHz and 10GHz Non regulated The unit supports two levels of privilege password regular user and administrator user Since Tx power level affect compliance of the unit with regulation rules precautions are built into the system to keep the end us...

Page 12: ...e Tx power according to the antenna gain and regulatory For example For integrated antenna of 23 dBi the max allowed Tx power is 13 dBm 10 dBm in MIMO to meet the EIRP limitation of 36 dBm For integrated antenna of 28 5 dBi the max allowed Tx power is 7 dBm 4 dBm in MIMO to meet the EIRP limitation of 36 dBm FCC 4 9 GHz According to FCC part 90 1215 a 1 The maximum conducted output power should no...

Page 13: ...in the MBS following transition or 5 5 MHz if the station is in the LBS and UBS following transition except as provided in paragraph h 1 ii of this section As such the following limits apply Channel bandwidth MHz High power maximum conducted output power dBm 5 62 2 10 65 2 14 66 67 20 68 2 ...

Page 14: ... WipAir 8000 MIMO o Dual polarization Vertical Horizontal o Dual slant 45 degrees The MU and its SUs must be on the same polarization To verify antenna polarization please refer to the assembly instructions supplied with the antenna set The polarization of integrated antenna is marked on the backside Vertical polarization marked with arrow pointing up or down Horizontal polarization marked with ar...

Page 15: ...e 5 Rotate the antenna for maximum RSSI with zero PER on the installation window of the Link Manager To avoid saturation make sure the RSSI level does not exceed 25 dBm Note Do not stand in front of transmitting antenna Rotate the antenna from the rear side 6 Mount and secure the unit by fastening the mounting screws 2 2 3 3 4 4 2 2 U Us si in ng g t th he e b bu ui il lt t i in n R RS SS SI I b b...

Page 16: ...by fastening the mounting screws 7 Set the MU back to adaptive modulation AUTO for both uplink and downlink 8 Disable the RSSI buzzer To activate deactivate the buzzer manually use the Link Manager advanced window Note During this procedure do not disconnect the unit from power 2 2 3 3 5 5 S Se ea al li in ng g The outdoor unit must be sealed against rain with the rubber grommets RJ 45 ports of th...

Page 17: ...dix A Outdoor Cables Scheme The Indoor PoE Outlet side and Outdoor Unit side are crimped using RJ 45 tool Total length of the CAT5 cables must not exceed 100 meters The Outdoor Unit side is assembled according to the following steps Figure 2 5 Insert seal bracket grommet clamping plate on the cable Insert rubber seal grommet on the cable Crimp the RJ 45 Plug Figure 2 5 Cable preparation for Outdoo...

Page 18: ...ation Guide Page 18 of 28 Figure 2 6 Cable assembly to Outdoor Unit Figure 2 7 Cable insertion to Outdoor Unit Fasten the seal bracket Figure 2 8 The unused port should be left sealed Figure 2 8 Cable connection to Outdoor Unit ...

Page 19: ...door Unit cable 2 Plug the Outdoor Unit cable to the RJ 45 Jack marked PWR LAN OUT 3 Plug standard CAT5 cable from the PC to the RJ 45 Jack marked LAN IN 4 Plug the AC Input to the power 100 240VAC Note Do not attach standard CAT5 cable from the PC or other network device to the Indoor Unit RJ 45 jack marked PWR LAN OUT It may damage the PC s Ethernet interface To 100 240VAC To Outdoor Unit MU SU ...

Page 20: ... 3 to 6 feet extra to allow for strain relief Figure 2 10 Ground Connection to Outdoor Unit Protection from lightning US National Electric Department of Energy Handbook 1996 specifies that radio and television lead in cables must have adequate surge protection at or near the point of entry to the building The code specifies that any shielded cable from a detached antenna must have the shield direc...

Page 21: ...n between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device must accept any interference received including interference that may cause undesired operation Any unauthorized modification or changes to this device without the express approval...

Page 22: ... synchronization signal is generated by an external GPS 1 PPS when synchronizing multiple towers or by a master MU when synchronizing units on the same tower External synchronization Synchronize multiple towers with one GPS unit per tower Figure 2 12 External time synchronization Internal synchronization Synchronize multiple MUs on one tower without any external device Figure 2 13 Internal time sy...

Page 23: ...ypical per SU Data Latency Layer 2 Bridge VLAN QinQ VLAN broadcast IP filters DHCP server Network Modes 100 240 VAC 47 63 Hz to 48 VDC Power over Ethernet PoE Power 7Watt Power Consumption 19 x 19 x 4 cm 1Kg connectorized Mechanical 100 non condensing Rainproof Operating Humidity 40o c to 60o c Operating Temperature IP67 IP Rating RJ 45 Connector Type 2x 10 100 1000 Base T ODU Physical Interface 1...

Page 24: ...ou ut td do oo or r c ca ab bl le es s s sc ch he em me e Figure 4 1 Outdoor Cables Scheme Note In order to comply with 100 meter CAT5 cable Pins 1 2 must be a twisted pair wire Pins 3 6 must be a twisted pair wire Pins 4 5 must be a twisted pair wire Pins 7 8 must be a twisted pair wire ...

Page 25: ...75 5775 11 5780 5780 5780 5780 12 5785 5785 5785 5785 13 5790 5790 5790 5790 14 5795 5795 5795 5795 15 5800 5800 5800 5800 16 5805 5805 5805 5805 17 5810 5810 5810 5810 18 5815 5815 5815 5815 19 5820 5820 5820 5820 20 5825 5825 5825 5825 21 5830 5830 5830 5830 22 5835 5835 5835 23 5840 5840 5840 24 5845 Figure 5 1 FCC 5 GHz RF channel List 5 5 2 2 F FC CC C o op pe er ra at ti in ng g B Ba an nd d...

Page 26: ...WaveIP Ltd WipAir Installation Guide Page 26 of 28 5 5 4 4 O Op pe er ra at ti in ng g B Ba an nd ds s i in n M Me ex xi ic co o 5150 MHz 5350 MHz 5725 MHz 5850 MHz 4 95 GHz 4 99 GHz Public Safety bands ...

Page 27: ...5 Dish DP 5X 285D 005 28 27 dBi 4 9 GHz 2ft Figure 6 1 WipAir 5GHz integrated external antennas Antenna Type Model Gain dBi Dimension mm Flat panel DA 24 135D 045 13 5 200x200x15 DA 24 160D 020 16 305x305x15 DP 24 175D 020 17 5 371x371x40 SDP 24 150D 060 15 430x165x35 SDP 24 140D 090 14 430x165x35 SDP 24 160D 090 16 700 133 57 SDP 24 150D 120 15 700 133 57 SA 24 150V 060 15 450x165x35 SA 24 140V 0...

Page 28: ...malfunction A good grounding system disperses most of the surge energy from a lightning strike away from the building and equipment The remaining energy on the Ethernet cable shield and conductors can be directed safely to ground by installing a lightning arrestor in series with the cable If you have determined that it is appropriate to install lightning protection for your system the following ge...