1128500
WPC 2000 User Manual
5-20
Troubleshooting
Internal Memory Failures
- or -
Problem: There is a problem with the main or second processor on the WPC 2000 Main
Processor board. The board may need to be serviced or replaced. Errors are as
follows:
Remedy: Press Reset/Select. If the error persists, contact Wintriss Tech. Support for
assistance or replacement of the Main Processor board or firmware chip.
Resetting Ross DM2 DSV Faults
If your Ross DM2 DSV faults when air is first applied to the unit, one or both poppets may
have been jarred into a faulted position during shipment. When the poppets are faulted, input
air can escape through the muffler port. To reset the fault, air must be applied to DSV to
return the poppets to their unfaulted position.
If the fault occurs before the unit has been wired, the problem will be signalled by air escaping
from the muffler port when input air is applied to the DSV. To reset the unit, press the brass
button on the bottom of the Reset solenoid while air is being applied to the DSV (see
Figure 5-4, page 5-21).
If the fault occurs after the unit has been wired, an F47 error will appear on the WPC 2000
display. To clear the fault and reset the DSV, press Reset/Select and turn the Stroke Select
key switch to OFF, then to one of the other operating modes (see page 5-12).
If you have trouble resetting the DSV, the problem may be that both poppets are faulted,
requiring more air for a reset than can be supplied by the system. In this case, try resetting the
unit with the muffler port obstructed. Place your hands or a rag or plastic packaging material
over the muffler to restrict the escape of air, then actuate the Reset solenoid.
F90* through F98*
H90* through H98*
F90 or H90 Program memory checksum 1 is incorrect
F91 or H91 Program memory checksum 2 is incorrect
F95 or H95 Angle table memory checksum is incorrect
F96 or H96 RAM memory failed memory test
F97 or H97 No angle setup is loaded
F98 or H98 The option switch image changed during operation
F99 or H99 +24 Vdc failed, or the fuse blew
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......