Installation of Shadow VI-WPC Control Board Appendix C
page 127
Table C-4. Shadow-WPC Board TB4 to WPC
Shadow VI-WPC TB4
terminal #
WPC terminal #
Pin #1 (OUT 1)
Pin #77 (LIGHT CURTAIN A 1 INPUT -)
Pin #2 (GND)
Pin #44 (GND)
Pin #3 (OUT 2)
Pin #87 (LIGHT CURTAIN A 2 INPUT -)
Pin #4 (RST)
no connection
Pin #5 (INT)
Pin #27 (LIGHT CURTAIN 1 ENABLE)
Making settings on the control board
These are the settings to make on the Shadow VI-WPC board.
Floating window setting
The floating window feature provides a means for the random bypass of only one beam of
the light curtain (refer to Chapters 1 and 3 of this manual for more detail).
To set, locate switch block S1 (illustrated below). This switch is situated at the lower half of
the board to the left of the black reset button (see Figure C-3 for location of components).
The "off" setting (default) disables the floating window option. When this feature is enabled
("on"), the floating window indicators on the control board and at the receiver will flash on
and off.
off
on
S1
Figure C-6. Floating Window Switch S1