1107200
Shadow VI User Manual
page 126 Appendix C
Installation of Shadow VI-WPC Control Board
Table C-3. Shadow-WPC Board TB1 to WPC
Shadow VI-WPC TB1 Pin #
WPC Pin #
Pin #1 (L1)
125 (L1)
Pin #2 (L2)
126 (L2)
Pin #3 (GND)
127 (GND)
Pin #4 (PE)
Shield
Next, locate the 115V-230V voltage selector switch (S2) on the control board. It is located at
the upper right corner of the board.
The setting on this board must match the voltage setting
at WPC.
The default setting is 115V ("115V" displays in the switch cavity). If the WPC is
set for 230V AC power, push down on the handle for the Shadow VI control board to display
"230V".
115V
Handle.
Push
down
for 230V
Figure C-5. Setting Voltage Selector Switch S2
Connecting Stop Circuits to WPC
Wiring the Shadow VI-WPC board to WPC's emergency stop circuitry ensures that whenever
an obstruction or intrusion is detected, the press will stop as quickly as WPC will permit.
NOTICE
Whenever Shadow VI stops the press, WPC will display a numeric error code on the LED
display. If SmartPAC is interfaced with WPC, an error message will appear on SmartPAC's
LCD display.
To make proper wiring connections to WPC, consult in the manual:
•
Table C-4 TB4 Wiring table
•
Figure 8 (Shadow VI-WPC wiring schematic) at the end of the manual
Connect to terminal block TB4 located at the lower half of the Shadow VI-WPC board (see
Figure C-3 for location of components).
The following is the wiring table for stop circuits.
Summary of Contents for Shadow VI
Page 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Page 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......