Appendix B
Shadow VI Panel Mount
Final assembly
Once the final checkout has been confirmed and Shadow is working satisfactorily while it
has been sitting outside the enclosure, you are ready to completely install the Shadow VI
panel mount into your enclosure.
Remember earlier you had cut out a hole in your panel enclosure. Mount the Shadow panel
assembly into this cavity using the ten 1/4-20 screws. Refer to Figure B-2 for mounting and
cutout dimensions for Shadow VI panel and your enclosure.
cutout size
3" x 9"
(7.6 x 22.9 cm)
3.5 (8.9)
10
(25.4)
0.218 dia.
(0.55)
10 plcs.
9.5
(24.1)
4
(10.2)
2 plcs.
8
(20.3)
2.5 (6.4)
4 (10.2)
allow minimum
8" clearance
behind panel
mounting plane
Figure B-2. Shadow VI Panel Mount Control Dimensions