AutoSet User Manual
1137200
Troubleshooting
5-5
If you remount or replace a strain link, you must rezero the strain link (refer to
, page 3-1). When replacing a strain link, you do not have to recalibrate AutoSet unless
you move the strain link to a different location.
Troubleshooting Common AutoSet Problems
The following sections show you how to troubleshoot several common AutoSet problems.
Load or Setpoints LED Displays Are Blank
If no values appear in the Load and/or Setpoints LED displays, do the following:
•
Check to see whether you have power, referring to
check to see whether power is present on both sides of fuse F102 on the AutoSet processor
board (see Figure 2-4 or Figure 2-5).
•
Check the wiring of the strain links. Refer to
•
If you are still having difficulty, contact Wintriss Tech. Support.
Figure 5-4. AutoSet 1504 Plus Front Panel Displaying Offset Error
AutoSet 1504
®
WINTRISS LOAD ANALYZER
PLUS
SETPOINTS
RIGHT
LEFT
ZERO CAM
REAR LOAD
SETPOINTS
FRONT LOAD
TOTAL
DISPLAY
HIGH
RESET
REPEATABILITY
REVERSE
Flashing HI or
LO message on
channel at fault
Flashing Err
message
(AutoSet 1504 Only)
Flashing Err
message on
channel at fault