1137200
AutoSet User Manual
2-8
Installation
5.
Connect the ground (green or green/yellow) wire to the ground stud on the ceiling of the
enclosure at the top right, as shown in Figure 2-6. To make the connection, strip the
ground wire about 1/4” (6.4 mm) from the end, loosen the screw on the ground stud, slide
the wire into the hole, and tighten the screw to pin the wire in place.
6.
Remove the connector from terminal block TB103 at the top right of the AutoSet
processor board, and connect the remaining AC wires as shown in Figure 2-6 and
Table 2-1.
* Ground wire (green or green/yellow) should be connected to ground stud on ceiling of enclosure.
Figure 2-6. AC Power Connections
Table 2-1. AC Power and Stop Circuit Wiring Connections, TB103
Pin #
Label
Function
Wire Color *
1
HI
AC power
Black
2
NEU
AC power
White (115 VAC), Red (230 VAC)
3
GND
AC power
Not used
4
GND
AC power
Connected to case lug
5
N/O
Stop circuit
N.A.
6
C
Stop circuit
N.A.
HI NEU GND GND N/O C
TB103
1 2 3 4 5 6
Ground wire
(green or green-yellow)
to ground stud
Factory-installed
ground wire
(green-yellow)
to case lug
White (115 Vac) or red (230 Vac)
wire to NEU terminal (pin #2)
Black wire to HI terminal
(pin #1)