Cleaning and maintenance
|
8
|
English
Operating instructions CTR Series
|
89014478; 2020-06
|
41
8.4
Replace the container
Ø
Wear protective clothing, protective gloves and protective goggles.
Ø
Pull the suction tube carefully out of the empty container.
Ø
Ensure that both vent holes (1) in the caps are open.
Ø
Place suction tube in the new container.
Ø
Slide the cap slowly downwards until the container opening is closed.
The dosing device must be vented if air has entered the dosing hose. This occurs if the container is not replaced in time.
Ø
Access the following menu:
1
2
Item
Name
1
Rinse aid dosing device
2
Detergent dosing device
Ø
Press button 1 or 2.
ð
The dosing device is vented. (120 s)
Ø
Press button 1 or 2 again.
8.5
Change the chemical product
Crystallisation can occur as a result of mixing different chemical products, which can damage the dosing device.
Therefore, the dosing device and the dosing hoses must be flushed with water before a new chemical product is used.
If this is not done, the Winterhalter Gastronom GmbH warranty and product liability will be void.
Ø
Remove the suction tube from the container and place it in a water-filled container.
Ø
Access the following menu:
1
2
Item
Name
1
Rinse aid dosing device
2
Detergent dosing device
Ø
Press button 1 or 2.
ð
The button turns white, and the dosing device is activated (120 s).
ð
The dosing hoses and the dosing device are rinsed out with water.
Ø
As soon as the button goes dark, place the suction tube into the new container.
Ø
Press button 1 or 2 again.
ð
The button turns white, and the dosing device is activated (120 s).
ð
The water in the dosing hoses and dosing device is replaced by the new chemical product.
In addition, the dosage must also be reset.
Ø
To attain good wash results, commission an authorised service technician.