![WinSystems EBC-C384-D Manual Download Page 34](http://html.mh-extra.com/html/winsystems/ebc-c384-d/ebc-c384-d_manual_987929034.webp)
140703
DCD (COM3)
RXD (COM3)
TXD (COM3)
D
TR (COM3)
GND (COM3)
DCD (COM4)
RXD (COM4)
TXD (COM4)
D
TR (COM4)
GND (COM4)
(COM3) DSR
(COM3) R
TS
(COM3) CT
S
(COM3) RI
NC
(COM4) DSR
(COM4) R
TS
(COM4) CT
S
(COM4) RI
NC
J10
2 4 6 8 10 12 14 16 18 20
□ □ □ □ □ □ □ □ □ □
□ □ □ □ □ □ □ □ □ □
1 3 5 7 9 11 13 15 17 19
PCB Connector:
TEKA SVC210C405M123-0 (J10)
Mating Connector:
ITWPANCON 050-020-455A
COM3, COM4 [DB9 Male]
CBL-173-G-1-1.0
Serial
COM3
COM4
1
5
6
9
Pin
RS-232
RS-422
RS-485
1
DCD
N/A
N/A
2
RX
TX+
TX/RX+
3
TX
TX-
TX/RX-
4
DTR
N/A
N/A
5
GND
GND
GND
6
DSR
RX+
N/A
7
RTS
RX-
N/A
8
CTR
N/A
N/A
9
RI
N/A
N/A
Both ports are configured as Data Terminal Equipment (DTE). Both the send and receive registers of each port have a
16-byte FIFO. All serial ports have 16C550-compatible UARTs. The RS-232 has a charge pump to generate the plus
and minus voltages so the EBC-Z5xx only re5V to operate. An independent, software programmable baud rate
generator is selectable from 50 through 115.2 kbps. Individual modem handshake control signals are supported for all
ports.
SERIAL
J10 - COM3, COM4