![WinSystems EBC-C384-D Manual Download Page 22](http://html.mh-extra.com/html/winsystems/ebc-c384-d/ebc-c384-d_manual_987929022.webp)
140703
CONNECTOR REFERENCE
POWER
J6 - Power and Reset
Power is applied to the EBC-C384 via the connector at
J6
. WinSystems offers the cable
to simplify this
connection.
J6
+5V
GND
GND
+12V
Not Used
GND
+5V
-12V
ATX_PWRGOOD
PCB Connector:
MOLEX 26-60-6092 (J6)
Mating Connector: MOLEX 09-50-8093 (Housing)
MOLEX
08-58-0189
(Crimp)
CBL-236-G-2-1.5
□ □ □ □ □ □ □ □ □
1 2 3 4 5 6 7 8 9
PCB Connector:
MOLEX 22-29-2021 (J2)
Mating Connector: MOLEX 10-11-2023 (Housing)
MOLEX
08-55-0124
(Crimp)
J2 - Push Button Reset
□
□
J2
1
2
RESET
GND
WinSystems offers the cable
to simplify this connection.
J26
□
□
□
1
2
3
GND
VCC
TACH
J26 - Fan Power
Mating Connector:
MOLEX 22-11-2032 (J26)