SECTION 4
APPLIANCES & EQUIPMENT
4-6
4. Let the handle of the P-T valve snap shut.
5. Close the faucet and turn on the water supply
before switching the water heater on.
Manually operate the pressure temperature
relief valve at least once a year.
WATER HEATER BY-PASS
VALVE
Your coach is equipped with a water heater
by-pass valve for easier winterization of water
lines using RV antifreeze. See Plumbing Section
for valve location.
Turn the handle as shown to either by-pass or
flow through the water heater.
LP GAS FURNACE
Start Up:
1. Open the LP gas tank valve by turning fully
counterclockwise.
2. Move thermostat switch from OFF to HEAT
and press the Temp Selector button (Up/Down
arrows) until the desired temperature is shown
on the display.
3. Furnace fan will start to blow soon after
setting thermostat.
4. After about 30 seconds, the furnace burner
will light.
5. The furnace will now cycle off and on
automatically as the thermostat demands just
like a household furnace.
NOTE:If heat does not come out of the heat
ducts after a minute or so the burner is
not lit. Turn thermostat off for 3-5
minutes, check to be sure LP gas tank
valve is open and tank is not out of fuel,
then try steps 2-4 again. If it still will not
light after three attempts, go to Shut
Down steps and contact your dealer or a
local RV service center.
CAUTION
Leave by-pass valve handle in NORMAL
FLOW position if draining water and
blowing out water lines. Place in BYPASS
position ONLY when using antifreeze
solution in water lines.
Open
Lift handle straight out to open P-T
Normal
Flow
By-Pass
Mode
Move Thermostat switch to
Heat for furnace operation
Temp Selector