Winkler AG
▪
Englerstrasse 24
▪
D-69126 Heidelberg
▪
Tel. +49-6221-3646-0
▪
Fax: +49-6221-3646-40
▪
▪
www.winler.org
13 of 17
Rev.1.1.
3.
2022-09
Operating Insructions
Drum Heaters (0-90°C)
WOCP, WODPX, WODOK
Insulating lid completely open
By completely opening the insulating lid,
the canister can be easily transported.
The heating jacket does not need to be
removed, which saves time and effort.
9.
Commissioning (see Figure 9.1)
Before commissioning, make sure that the operating manual of the temperature controller is available in order to obtain
detailed information about the settings and the control behavior.
Fundamental (WRL430PW):
The hook and loop strip on the back of the temperature controller allows you to attach it
to the cover of the heating jacket. A hook and loop fleece pad on the heater is provided for this purpose, which is lo-
cated next to the cable with 0.3 m connection cable. Connect the 6+PE plug to the 6+PE socket of the temperature
controller. The drum heater is connected to the power supply using the controller connection cable (1). The controller
is switched on by pressing the up and down (2) keys simultaneously for a longer period of time. After switching on, the
controller performs a self-test (white indication light). If everything is OK, the display briefly lights up green (3) and
then drum heater begins heating. If an error is detected, an error message on display or signal LED (3) is displayed im-
mediately.
Usually, after switching on, the set temperature has not yet been reached. The status LED (3) flashes blue slowly. This
means that the heating is active and the set temperature has not yet been reached. If the temperature is within the
good range of the setpoint, the status LED (3) is permanently green. Note: The controllers are delivered with a basic
setting (4) of 40°C. In the delivery state, the controller switches on automatically. Detailed information can be found in
the controller operation manual.
.
Figure 9.1
Monitor the heating process and the behavior of the contents. If necessary, open the lid or bungholes of the IBC Con-
tainer so that it does not expand inadmissibly due to a pressure build-up during heating. In case of liquid leakage, im-
mediately take the IBC Container heater out of operation and remove it.
10.
Troubleshooting and problem solving
Please read these instructions before contacting us. These instructions are designed to answer frequently asked
questions. If you cannot identify the problem or need additional help, please contact your dealer or our service
department.