![WinGD X92DF Operation Manual Download Page 329](http://html1.mh-extra.com/html/wingd/x92df/x92df_operation-manual_986583329.webp)
Tab 6-14
FUEL SHARING (if applicable)
Item
Function
Effect
001
START AST button
Starts the engine in astern direction (for reversible engine)
002
STOP button
Stops the engine
003
START AHD button
Starts the engine in ahead direction
004
CTRL. TR. button
Sends a signal for a control transfer to this LDU-20
005
DIESEL button
Switches to diesel mode
006
GAS button
Starts transfer to gas mode operation
007
Fail Reset button
Resets a failure that occurred during gas preparation
NOTE:
Use this button only when you have done the related
measures to repair the failure.
008
Active mode
Shows the active operation mode (orange frame)
NOTE:
GFS - Gas Fuel Supply
009
Index button
Opens the INDEX page
010
Print button
Makes a screenshot of the current screen, refer to
011
Fuel Share request button
Requests fuel sharing mode
NOTE:
You have to set the value for the ratio of liquid fuel to
gas in the RCS.
X92DF
AA00-9606-15AAA-043B-A
Operation Manual
LDU-20 page - FUEL SHARING (if applicable)
Winterthur Gas & Diesel Ltd.
- 329 -
Issue 002 2020-08